Instruction book
• The compressor is automatically controlled and may be restarted automatically.
Initial start procedure
1. Check the oil level before starting.
The oil level should be between the oil filler neck (FC) and the bottom of the sight glass (Gl).
2920 7180 30
If the compressor has not run for the past 6 months, it is strongly recommended to
improve the lubrication of the compressor element before starting.
To do so:
1. Disconnect the inlet hose.
2. Remove the unloader (UA).
3. Pour approximately 0.75 l (0.20 US gal, 0.17 Imp gal) of compressor oil into the
compressor element inlet. For oil specifications, see section
4. Reinstall the unloader and reconnect the inlet hose.
Make sure that all connections are tight.
Location of unloader
Oil
specifications.
141