Image 9-6
1. If the coupling at the speed encoder end has been separated, use removable LOCTITE
Table 9-7
Thread size
M4
M5
M6
1. Check the elastic connecting link (coupling star) to ensure that it is in a good condition and
2. Mount the complete speed encoder.
SIMOTICS DC 1GH5
Operating Instructions 02/2016
Speed encoder mounting
to secure the lateral stud bold or set screw when the coupling is assembled and tighten
with the correct torques.
Tightening torques for mounting couplings
in the correct mounting position.
Tightening torque [Nm]
1.3
2.6
4.5
Maintenance
9.2 Repair