4. Specifications, Defect Inspection, and Repairs of Heater
1) Specifications
Category
Maker
Voltage
Power Consumption
Resistance
Current Desnity
Temperature Fuse
Thermister
Materials
Max. Temperature
Part Code
Water Heater
DWM30-999PG(영_SM).indd 38
Specifications
Note
1RCA
220V
1400 W ±5%
34.570hm
11.9
184°C
Included in heater
AISI321
WATER
3612804000
Water Temperature Sensor
1. Temperature Fuse of Water Heater (184 °C Cutoff
Type)
• If the heater is running without water due to a
malfunction in water level sensor and other
defects, it may cause fire. The inter temperature
fuse is designed to be cut off about a minute after
overheating to prevent such problems. The heater
temperature is set at around 270°C.
• The water heater must be used in water.