3) Inspection and Repairs of Water Inlet Valve
Defects
Descriptions
Water supply
Water is not
unavailable
supplied despite
the "drone"
Water supply
Water supply
unavailable
continues with
the power "ON"
Constant
Power is "OFF"
water supply
Constant leaks
(into tub)
on sides
Others
4) Defects and Relevant Parts
Unavailable
PCB
water
supply
Incessant
PCB
water
supply
Inlet Valve 1. Examine whether the water
Synchronous
Drain Motor
(Valve
Housing)
DWM30-999PG(영_SM).indd 36
Causes
Faucet is turned off. Check whether the faucet is turned on
Short coil
Check whether the inter-terminal
resistance of inlet valve is 4.3kΩ
Excessive impurities
Unplug the inlet hose and then check
on SUS filter
the impurities
Impurities in valve
Check the malfunctions in valve
Disconnected
Check the connection of connector
connector
with naked eyes
Coil wire
Check whether the inter-terminal
resistance of inlet valve is 4.3kΩ
Disconnection in
Check any disconnections in wiring
wiring
-> Inspect circuit
Defective water
See the inspection of "Water Level"
level sensor
defects
Inspect any openings and
Inspect any openings and blockages
blockages in pressure hoses
in pressure hoses
Defective valve
Check the malfunctions in valve
Check any leaks
Check any leaks from the sides of
from the sides of
inlet valve
inlet valve
1. Inspect the insertion of
Easily detachable if the
PCB pin
wire is pulled
2. Unavailable power or
Open or destroyed PCB
water supply to inlet valve
inlet circuit (Water relay
terminal
unavailable)
1. Water supply starts
Short circuit in PCB
promptly when the power
inlet circuit or water
is turned "ON".
relay (Incessant electric
transmission to valve)
Deformed water inlet
supply continues even when
valve bellows
the power supply is cut off
1. Examine the operation/
• Unclosed due to
water supply of inlet valve
impurities in
2. Examine the drainage
drainage housing
through the drainage hose
3. Check any impurities in
valve housing
Inpsection Method
and "cleanse" the filter
Housing on pin
connection not
properly inserted
Defective inlet
circuit
Short circuit in
water relay
Defective inlet
valve
• Impurities in
valve housing
• Impurities
• Error in returns
of synchronous
motor
36
PCB Error
Repair Method
Mode
Turn on the faucet
"IE"
Exchange the part if
"IE"
it is open
Remove impurities
"IE"
Exchange the inlet valve
"IE"
Reconnect the
"IE"
connector
Exchange the inlet
"IE"
valve
Exchange the
"IE"
harness
Exchange the water
"E2"
level sensor
Exchange the
"E2"
defective part
Exchange the inlet valve
-
Exchange the inlet
-
valve
Insert the housing
on pin connection
completely
Exchange the PCB
Exchange the PCB
Exchange the inlet
valve
• Remove impurities
• Remove impurities
• Exchange the
synchronous motor
16. 8. 23. 오전 10:10