4. DISPLAY SPECIFICATION
NR-CY54AG, NR-CY557G
PROCESS INSPECTION
IN-PROCESS INSPECTION
START
CONDITION
END
CONDITION
CONTENTS
FOR CONTROL
MANUAL DEFROST
AUTOGNOSIS
JUDGEMENT
NOISE MODE
CONTENTS
INSPECTION OF TEMP.
JUDGEMENT
INSPECTION OF
ILLUMINANCE SENSOR
JUDGEMENT
Freezer Control
Quick Freezing
Operate the following controls within 3 sec., within 30 sec., after power-on
while PC and FC door are open.
QUICK FREEZING BUTTON ➝ FREEZER CONTROL BUTTON ➝ QUICK
FREEZING BUTTON
1 Hold down QUICK FREEZING BUTTON for over a second.
(Manual defrost)
2 After 4 hours (Defrost start)
COMP : R 6 (62rps)
FC FAN : VF4 (Ultrahigh Speed)
HEATER : DEFROST HEATER OFF
LED : ECONAVI LED and FREEZER LED [ NORMAL ]
BRINKING (ON_1sec/OFF_1sec)
Hold down QUICK FREEZING BUTTON for over a sec.
During in-process inspection.
Indicate AUTOGNOSIS in which case abnormal condition.
For 45 sec., of the start of IN-PROCESS INSPECTION
COMP : R 7 (71rps)
For 30 min., of the start of IN-PROCESS INSPECTION
Normal or abnormality is displayed according to the range of drop of FCC
ALL FREEZER LED LIGHTING..........GOOD
ALL FREEZER LED BRINKING..........BAD
During IN-PROCESS INSPECTION
After 1 min., of the start of IN-PROCESS INSPECTION.
Abnormality is judged according to variation width of input voltage of
illuminance sensor.
ECONAVI LED EXTINCTION..........GOOD
ECONAVI LED LIGHTING...............BAD
- 6 -
DISPLAY
ECONAVI
INVERTER
Freezer Control button
Quick Freezing button