Display Specification - Panasonic NR-BX418XS Service Manual

Table of Contents

Advertisement

NR-BX418/NR-BX468/NR-BX41B/NR-BX46B

4. DISPLAY SPECIFICATION

NR-BX418VS, NR-BX41BVW, NR-BX418XS, NR-BW418GW/GK, NR-BX468XS,
NR-BX46BXS, NR-BX468GW/GK
PROCESS INSPECTION
IN-PROCESS INSPECTION
START
CONDITION
END
CONDITION
CONTENTS
FOR CONTROL
MANUAL DEFROST
AUTO DIAGNOSIS
JUDGEMENT
NOISE MODE
CONTENTS
INSPECTION OF TEMP.
JUDGEMENT
INSPECTION OF
ILLUMINANCE SENSOR
JUDGEMENT
Operate the following control within 3 sec. , within 30 sec., after power-on
while PC door are open.
Push Door switch more than 3 time but not over 10 time
1. Push Door switch more than 3 time but not over 10 time
( Manual defrost )
2. After 4 hours ( Defrost start )
COMP. : R5 (52 rps )
FC FAN : High speed
HEATER : Defrost heater off
LED : ECONAVI LED has only for model which have operation panel
BRINKING (ON_1sec/OFF_1sec )
Push Door switch more than 3 time but not over 10 time
During IN-PROCESS INSPECTION
Indicate AUTO DIAGNOSIS in which case abnormal condition.
For 45 sec., of the start of IN-PROCESS INSPECTION
COMP. : R5 (52 rps )
For 30 min., of the start of IN-PROCESS INSPECTION
Normal or abnormality is displayed according to the range of drop of FCC
ALL FREEZER LED LIGHTING..........GOOD
ALL FREEZER LED BRINKING..........BAD
During IN-PROCESS INSPECTION
After 1 min., of the start of IN-PROCESS INSPECTION
Abnormality is judged according to variation width of input voltage of
illuminance sensor.
ECONAVI LED EXTINCTION...........GOOD
ECONAVI LED BRINKING.................BAD
- 7 -
DISPLAY
ECONAVI
Quick freezing LED light
Fridge control button
Prime fresh control button
Freezer control button