8.6 Interfaces

Interface
IF
TNC jack, lightning protected
RF (SU-E)
N-Type jack , lightning protected
Ethernet
Monitor
Power
12 VDC via the IF cable

8.7 Electrical, Mechanical and Environmental

Outdoor Unit
Power
12 VDC from SU-NI via the IF cable
Mechanical
SU-RA: 30cm x 30cm x 7.2 cm, 3 kg
SU-RE: 30cm x 12cm x 5 cm, 2.2 kg.
0
Operating
-40
Temperature
Operating
5%-95% non condensing,
Humidity
Weather protected

8.8 Standards Compliance, General

EMC
Safety
Environmental
Surge Immunity
BreezeACCESS 2.4 Series
Outdoor unit
0
C to 60
C
FCC part 15, EN 300 826
UL 1950, EN 60950
GR - 63 - CORE (Bellcore), ETS 300 019
EN 61000-4-5, test level 3 (2kV)
SU-NI indoor unit
TNC jack, lightning protected
10Base-T (RJ-45) with 2 embedded LEDs
3-pin low profile
DC Plug for the SU-PS power supply
SU-NI Indoor Unit
SU-NI: 12VDC/2.5A from SU-PS
SU-PS: 100 – 240 VAC, 47-63 Hz
SU-NI: 13cm x 8.6cm x 3cm, 0.5 kg.
SU-PS: 10cm x 6.5cm x 3.5cm, 0.4 kg.
0
0
0
C to 40
C
5%-95% non condensing