3. CONFIGURING SYSTEM PARAMETERS

After completing the installation process, as described in the preceding section,
proceed with the configuration of the basic system parameters.
This section covers the configuration of basic installation parameters. Refer to the
Administration Manual for information related to other parameters.
Note:

3.1 Getting Started with the Local Terminal

1. Connect one end of the Monitor cable to the MON jack on the front panel of
the SU-NI Indoor unit. Connect the second end of the cable to the COM port
of the terminal. The COM port connector on the Monitor cable is a 9 pin
D-type plug.
2. Run a terminal emulation program (e.g., ProComm or Windows
HyperTerminal) using the following setup.
3. Press Enter. The Select Access Level menu appears. Select the access level
according to your authorized access level. You will be requested to enter
your password. After entering the correct password press enter. The main
menu appears (refer to Table 3-1).
BreezeACCESS 2.4 Series
Optionally, the product can be configured using Telnet over the Ethernet
port, after setting IP address. For further information, see Appendix A.
Baud rate
9600
Data bits
8
Stop bits
1
Parity
None
Flow Control
Xon/Xoff
Connector
Available Com Port
Configuring System Parameters
15
SU-A/E Subscriber Units Installation Manual