2.5 Installing the Outdoor Unit

2.5.1 Pole Mounting the Outdoor Unit

The Outdoor unit can be secured to the pole using one of the following options:
Figure 2-3 shows the locations of the u-bolt holes, band grooves and screw holes
on the rear side of the Outdoor unit.
Figure 2-4 illustrates the method of installing an SU-RA Outdoor unit on a pole,
using the brackets and open-ended screws.
Figure 2-5 illustrates the method of installing an SU-RE Outdoor unit on a pole,
using the brackets and open-ended screws.
Note:
BreezeACCESS 2.4 Series
Special brackets and open-ended screws (supplied with each unit). There
are two pairs of screw holes on the back of the unit, allowing use of the
special brackets with various pole widths.
U-bolts – size A (inner installation holes, up to 2" pole).
U-bolt – size B (outside installation holes, up to 3" pole).
Metal bands (9/16" wide, minimum 12" long)
Make sure to install the unit with the bottom panel (the panel with the IF
connector) facing downward.
Grooves for Insertion of 9/16" Metal Band

Figure 2-3. Holes/Grooves/Screw holes

Size B U-Bolt Holes (3" Pole)
Size A U-Bolt
Holes (2" Pole)
Bracket Screw Holes