Krom Schroder VGP10 Operating Instructions Manual

Solenoid valve

Advertisement

Quick Links

34429700
D
GB
F
NL
I
TR
CZ
PL
RUS
H
 
Operating instructions
Solenoid valve VGP
Contents
Solenoid valve VGP . . . . . . . . . . . . . . . . . . . . . 
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Checking the usage . . . . . . . . . . . . . . . . . . . . . 2
Intended use . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Type code . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Part designations . . . . . . . . . . . . . . . . . . . . . . . . 2
Type label. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Tightness test . . . . . . . . . . . . . . . . . . . . . . . . . . 3
Replacing the actuator . . . . . . . . . . . . . . . . . . 4
VGP 10-15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
VGP 20-25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
VGP 10-15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
VGP 20-25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . 7
Designed lifetime . . . . . . . . . . . . . . . . . . . . . . . . 7
Logistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Certification . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Declaration of conformity . . . . . . . . . . . . . . . . . . 8
Approval for Australia . . . . . . . . . . . . . . . . . . . . . 8
Eurasian Customs Union . . . . . . . . . . . . . . . . . . 8
Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
E
DK
S
N
P
GR
www.docuthek.com
Safety
Please read and keep in a safe place
Please read through these instructions
carefully before installing or operating. Following the
installation, pass the instructions on to the opera-
tor. This unit must be installed and commissioned
in accordance with the regulations and standards
in force. These instructions can also be found at
www.docuthek.com.
Explanation of symbols
• ,  , 2 , 3 ... = Action
= Instruction
Liability
We will not be held liable for damage resulting from
non-observance of the instructions and non-com-
pliant use.
Safety instructions
Information that is relevant for safety is indicated in
the instructions as follows:
DANGER
Indicates potentially fatal situations.
WARNING
Indicates possible danger to life and limb.
CAUTION
Indicates possible material damage.
All interventions may only be carried out by qualified
gas technicians. Electrical interventions may only be
carried out by qualified electricians.
Conversion, spare parts
All technical changes are prohibited. Only use OEM
spare parts.
Changes to edition 05.
The following chapters have been changed:
- Installation
- Certification
GB-1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VGP10 and is the answer not in the manual?

Questions and answers

Summary of Contents for Krom Schroder VGP10

  • Page 1: Table Of Contents

    Safety 34429700 Please read and keep in a safe place www.docuthek.com   Please read through these instructions Operating instructions carefully before installing or operating. Following the Solenoid valve VGP installation, pass the instructions on to the opera- tor. This unit must be installed and commissioned in accordance with the regulations and standards in force.
  • Page 2: Checking The Usage

    Checking the usage Installation Intended use CAUTION Please observe the following to ensure that the VGP Gas solenoid valve for safeguarding gas or air on is not damaged during installation and operation: various appliances. – Do not clamp the unit in a vice. Only secure the This function is only guaranteed when used within flange by holding the octagon with a suitable the specified limits –...
  • Page 3: Wiring

    Wiring Tightness test WARNING CAUTION Please observe the following to ensure that the VGP Electric shocks can be fatal! Before working on is not damaged during the tightness test: possible live components, ensure the unit is discon- – Check max. inlet pressure – see type label. nected from the power supply.
  • Page 4: Replacing The Actuator

    4 The unit is ready for operation. Replacing the actuator 5 Release the gas supply. ▷ We recommend replacing the entire actuator set when replacing the actuator. Maintenance ▷ Actuator set VGP 10-15 comprises the actuator, ▷ In order to ensure smooth operation: check the 1 x O-ring, 1 x seal and 1 x quick fastener.
  • Page 5: Vgp 20-25

    CAUTION Please observe the following to ensure that the VGP is not damaged during subsequent operation: – Install the closing spring in the correct position. Ensure that the catch of the closing spring is positioned in the opening of the valve disc. VGP 20-25 ▷...
  • Page 6: Assistance In The Event Of Malfunction

    27 Tightness OK: the unit is ready for operation. ! Guiding elements bent. Incorrect handling when 28 Open the pipeline again and release the gas installing the unit. supply. Assistance in the event of malfunction WARNING • Dismantle the unit and return it to the manufac- Electric shocks can be fatal! Before working on turer.
  • Page 7: Technical Data

    Designed lifetime Technical data This information on the designed lifetime is based on Gas types: natural gas, town gas, LPG (gaseous), using the product in accordance with these operating biogas (max. 0.1 %-by-vol. H S) or clean air; instructions. Once the designed lifetime has been other gases on request.
  • Page 8: Certification

    Approval for Australia Certification Declaration of conformity Australian Gas Association, Approval No.: 5567 www.aga.asn.au/product_directory We, the manufacturer, hereby declare that the product Eurasian Customs Union VGP, marked with product ID No. CE-0063BL1554, complies with the requirements of the listed Direc- tives and Standards. Directives: The product VGP meets the technical specifications –...

This manual is also suitable for:

Vgp 20Vgp 15Vgp 25

Table of Contents