Lid Switch/Lock Assembly

The lid switch and the lid lock are both together in
one part.
The Lid Switch requires 120 VAC to activate the
locking mechanism. The approximate resistance
of the lock coil is 70 ohms from red to yellow at
the J513 board connector. Check the lid switch
continuity of the lid switch between red and violet
at the same connector.
Lid Switch/Lock Assembly Removal
To remove the lid switch/lock assembly, the bezel
Bezel
The bezel is held in place by the tabs that extend
through the body of the lock assembly.
1. Reach under the top cover to release the
tabs. Push out and up on the tabs.
Tabs
2. Using a small screwdriver, push down gently
on the tab that prevents the lock assembly
from moving.
3.
disengage the right lock body tab. Then slide
to the right, allowing the lock assembly to
disengage from the top cover.
4. Slide the lock assembly from under the top
cover and disconnect the harness connector
from the lock assembly.
Lid Switch/Lock Assembly Reinstallation
1. Reconnect the harness connector and slide
the lock assembly into position under the top
cover.
2. Bring the left side tab of the lock assembly up
3. Push up on the lock assembly and slide to the
right. This will clip in place.
4. Push the bezel through the top cover securing
the lid switch/lock assembly in position. The
bezel can only go on in one direction. If
forced into position incorrectly, it can damage
the lock assembly.