Water Levels - GE GTW750CPLDG Technical Service Manual

27 inch
Hide thumbs Also See for GTW750CPLDG:
Table of Contents

Advertisement

Main Board: 120 VAC to the J101
Recirculation Pump: Should read
approximately 31.7 ohms - 120 VAC
Drain Pump: Should read approximately
13.2 ohms - 120 VAC
Mode Shifter Motor: Should read
approximately 5.7k ohms - 120 VAC
Water Valves: Should read approximately
1.3k ohms – 120 VAC
Lid Lock Position Locked: Locked pin 3 to
pin 1 approximately 70 ohms - 120 VAC
checked between pins 1 and 2 with the lid
closed

Water Levels

Approximate Minimum Water Levels
Impeller: 7 gallons or 3 in. deep from the bottom
of the basket.
Continuity is
Approximate Maximum Water Levels
Impeller: 26 gallons or 13-1/2 in. deep from the
bottom of the basket. Press and hold the Deep
Fill button for 3 seconds to achieve.
Impeller Bulky setting water level is 26 gallons or
12-3/4 in. deep from the bottom of the basket.
– 18 –
: 12 VDC / 7.5 VDC
Hall Sensor: 9 VDC pin 3 to pin 2
Pressure Sensor: (See Pressure Sensor
in the Fill System section of this service
guide.)
-
-

Hide quick links: