Warranty; Installation - Pentair Berkeley BPD Series Owner's Manual

Corrosion resistant self-priming centrifugal pump
Table of Contents

Advertisement

Available languages

Available languages

Installation

Dirt and Scale Plug Pump and Pipes!
Use New Pipe for Best Results.
Pump
Body
Clean Flow!
Figure 1 – No Dirt or Scale in Suction
Pipe
Figure 2 – Foot Valve Must Work
Freely
PERFORMANCE CHART (in gallons per minute) – High Head
BPDH10­L
Disch.
Press
5'
10'
15'
PSI
10
55
49
48
15
51
46
45
20
45
42
39
25
38
35
32
30
31
28
24
35
23
19
16
40
17
13
8
45
50
Models BPDH10-L and BPDH15-L have 2" NPT suction and 1-1/2" NPT discharge.
Models BPDH20-L and BPDH25-L have 2" NPT suction and discharge.
BEFORE YOU INSTALL YOUR PUMP
NOTICE: Well must not be more than 20' depth to water.
1. Long runs and many fittings increase friction and reduce flow. Locate
pump as close to well as possible: use as few elbows and fittings as
possible.
2. Be sure well is clear of sand. Sand will plug the pump and void the

warranty.

3. Protect pump and all piping from freezing. Freezing will split pipe,
damage pump and void the warranty. Check locally for frost protection
requirements (usually pipe must be 12" below frost line and pump must
be insulated).
4. Be sure all pipes and foot valve are clean and in good shape.
5. No air pockets in suction pipe.
From
Well
6. No leaks in suction pipe. Use PTFE pipe thread sealant tape to seal pipe
1096 0697
joints.
7. Unions installed near pump and well will aid in servicing. Leave room
to use wrenches.
8.
DO NOT use in a booster appli cation.
NOTICE: Use the installation method below which matches your well type.
Sags Allow Air Pockets
If Air Pockets Form, Water Won't Flow.
Keep Pipe Straight and Angled up to Pump.
1100 0697
Figure 3 – No Air Pockets in Suction
Pipe
BPDH15­L
20'
5'
10'
Capacity – Gallons Per Minute
45
67
61
44
66
58
37
61
56
29
55
52
20
48
45
11
39
37
33
27
18
14
Pump body may explode if used as a booster pump.
No Sags
1101 0697
BPDH20­L
Distance Above Water
15'
20'
5'
10'
56
46
69
67
55
45
65
63
54
44
59
56
51
43
52
50
44
38
47
45
34
28
42
38
20
11
34
30
8
25
17
14
7
Use PTFE pipe thread sealant tape or pipe joint
compound approved for use on PVC.
No air leaks In
Suction pipe.
If air flows
water won't
Use PTFE tape.
Figure 4 – Suction Pipe Must Not Leak
BPDH25­L
15'
20'
5'
10'
65
62
92
83
60
58
86
79
54
52
80
76
48
45
73
71
42
40
66
66
35
32
60
60
27
23
55
54
10
47
46
40
38
4
15'
20'
81
78
78
76
75
74
70
69
65
64
59
58
53
52
46
45
37
36

Hide quick links:

Advertisement

Table of Contents
loading