Page 2
Short length of straight pipe after reducer Tee and Priming Plug Important: Stop Priming All connections must Valve Plug be air tight Discharge Street Elbow to service Support suction pipe Union Eccentric Reducer, as required, so that Straight side up pump does not take Solid, level weight of pipe...
Page 3
PIPING - GENERAL DISCHARGE PIPING Support both suction and discharge piping independently at Increase pipe size from pump discharge port as shown in a point near the pump to avoid putting a strain on the pump Table I. Figure 1 (Page 2) depicts a recommended run of pipe housing.
Page 4
ELECTRICAL Low Voltage High Voltage Blue Blue Blue Black Tracer Black Tracer Purple Black Purple Black White White White 115/230V Dual Voltage 230V Single Voltage 3320 0998 WG Figure 3 – 115/230V Dual Voltage and 230V Single Voltage TEFC Wiring Diagram 2.
SERVICE PUMP SERVICE INSTALLATION OF FLOATING SEAT (Figure 4C) This centrifugal pump requires little or no service other than reasonable care and periodic cleaning. Occasionally, howev- 1. Clean polished surface of floating (ceramic) seat with er, a shaft seal (Key No. 4, Page 6) may become damaged clean cloth.
Page 11
TROUBLE - CAUSES AND REMEDY TROUBLE AND CAUSE REMEDY FAILURE TO PUMP 1. Pump not properly primed. 1. Make sure pump casing and suction line are full of water. See priming instructions. REDUCED CAPACITY AND/OR HEAD 1. Air pockets or leaks in suction line. 1.