168 Actual signals and parameters
Name/Value

22 ACCEL/DECEL

2202 ACCELER
2203 DECELER
TIME 1
PROFILE
MESSAGES
MESSAGES
5308 EFB UART
ERRORS
5309 EFB STATUS
5310 EFB PAR 10
5311 EFB PAR 11
5312 EFB PAR 12
5313 EFB PAR 13
5314 EFB PAR 14
5315 EFB PAR 15
5316 EFB PAR 16
5317 EFB PAR 17
5318 EFB PAR 18
www.aotewell.com
Description
Acceleration and deceleration times. See group
ACCEL/DECEL
in the list of all parameters.
Defines the acceleration time 1.
Defines the deceleration time 1.
Contains the identification and program version of the
protocol.
Note: You can reset this parameter only with parameter
9802 COMM PROT
SEL.
Defines the address of the device. Two units with the same
address are not allowed on-line.
Defines the use of parity and stop bit(s) and the data length.
The same setting must be used in all on-line stations.
Number of messages with an CRC (cyclic redundancy
check) error received by the drive. If the number is high,
Status of the EFB protocol.
Selects an actual value to be mapped to Modbus register
40005.
Selects an actual value to be mapped to Modbus register
40006.
Selects an actual value to be mapped to Modbus register
40007.
Selects an actual value to be mapped to Modbus register
40008.
Selects an actual value to be mapped to Modbus register
40009.
Selects an actual value to be mapped to Modbus register
40010.
Selects an actual value to be mapped to Modbus register
40011.
Selects an actual value to be mapped to Modbus register
40012.
For Modbus: Sets an additional delay before the drive
begins transmitting response to the master request.
sales@aotewell.com
on page 287.
on page 302.
Industry Automation
Def/FbEq
22
5.0 s
5.0 s
Fieldbus
-
1
9.6 kbit/s
8 NONE 1
ABB DRV
LIM
0
0
0
IDLE
0
0
0
0
0
0
0
0
0