Problem
Suction power is weak.
The vacuum does not work.
Sudden loss of power.
Dirt and debris are blowing
through exhaust vent.
All other service should be performed by the service agent where your CleanMax vacuum was purchased.
• Keep machine and all accessories clean and in good operating condition.
• Replace the bag when it is 2/3 full.
• Replace the filters once a year or as needed.
• Always use genuine CleanMax filters and parts, as use of other products may result in poor cleaning or filtration
performance. CleanMax filtration products are designed for maximum performance.
• Store machine carefully in a dry area.
• For optimum cleaning performance and safety, follow your owner's manual.

Troubleshooting

Check Point
• Vacuum bag
• Wand or hose
• Filters
• Power cord
• Thermal reset
• Filters

For Best Performance

10
Possible Solution
• If the vacuum bag is 2/3 full, replace it.
• If clogged or blocked, remove the object.
• Clean or replace filters.
Insert the power plug firmly into an electrical
outlet.
Turn off vacuum and unplug from electrical
outlet. Let vacuum cool down for at least 30
minutes before turning back on. Check for clogs.
Replace vacuum bag.
Make sure filters are clean, dry and installed
correctly.