Connecting Pin Assignments - Sharp XV-Z200U Operation Manual

Sharp projetor operation manual xv-z200u
Hide thumbs Also See for XV-Z200U:
Table of Contents

Advertisement

Connecting Pin Assignments

DVI-I (INPUT 2 / DIGITAL INPUT) port : 29 pin connector
9
~
16
• • • • • • • • •
• • • • • • • • •
1
2
~
7
8
• • • •
• • • •
17
24
~
18
• • • •
• • • •
23
• DVI Analog RGB Input
Pin No. Signal
Pin No. Signal
1
Not connected
2
Not connected
3
Not connected
4
Not connected
5
Not connected
6
DDC clock
7
DDC data
8
Vertical sync
9
Not connected
10
Not connected
11
Not connected
12
Not connected
13
Not connected
14
+5V power
15
Ground
RS-232C Port: 9-pin D-sub male connector
1 2 3 4 5
6 7 8 9
-64
• DVI Digital INPUT
Pin No. Signal
1
2
3
4
C1
5
C2
6
C4
7
C5
8
C3
9
10
11
12
13
14
15
16
Hot plug detection
17
Not connected
18
Not connected
19
Not connected
20
Not connected
21
Not connected
22
Not connected
23
Not connected
24
Not connected
C1
Analog input Red
C2
Analog input Green
C3
Analog input Blue
C4
Horizontal sync
C5
Ground
Pin No. Signal
Name
1
2
RD
Receive Data
3
SD
Send Data
4
Reserved
5
SG
Signal Ground
6
Reserved
7
Reserved
8
Reserved
9
Pin No. Signal
T.M.D.S data 2–
16
T.M.D.S data 2+
17
T.M.D.S data 2 shield
18
Not connected
19
Not connected
20
DDC clock
21
DDC data
22
Not connected
23
T.M.D.S data 1–
24
T.M.D.S data 1+
C1
T.M.D.S data 1 shield
C2
Not connected
C3
Not connected
C4
+5V power
C5
Ground
• DVI Analog Component Input
Pin No. Signal
Pin No. Signal
1
Not connected
2
Not connected
3
Not connected
4
Not connected
5
Not connected
6
Not connected
7
Not connected
8
Not connected
9
Not connected
10
Not connected
11
Not connected
12
Not connected
13
Not connected
14
Not connected
15
Ground
I/O
Input
Output
Hot plug detection
T.M.D.S data 0–
T.M.D.S data 0+
T.M.D.S data 0 shield
Not connected
Not connected
T.M.D.S clock shield
T.M.D.S clock+
T.M.D.S clock–
Not connected
Not connected
Not connected
Not connected
Ground
16
Not connected
17
Not connected
18
Not connected
19
Not connected
20
Not connected
21
Not connected
22
Not connected
23
Not connected
24
Not connected
C1
Analog input Pr/Cr
C2
Analog input Y
C3
Analog input Pb/Cb
C4
Not connected
C5
Ground
Reference
Not connected
Connected to internal circuit
Connected to internal circuit
Connected to internal circuit
Connected to internal circuit
Connected to internal circuit
Connected to internal circuit
Connected to internal circuit
Not connected

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xvz200

Table of Contents