Maintenance - Hyundai HY3500Ei User Manual

Petrol inverter generator
Table of Contents

Advertisement

7. MAINTENANCE

6.
WARNING
Before cleaning, inspecting or repairing your unit, you MUST make sure that the
engine has stopped and allowed to cool.
You MUST disconnect the spark plug HT lead cap to prevent any accidental starting.
CAUTION
ALWAYS refuel in a well-ventilated area with the engine off and the spark plug HT
cap removed.
Whilst carrying out maintenance you MUST wear appropriate Personal Protective
Equipment (PPE). Suggested PPE Sturdy footwear, work gloves, long trousers and
hearing protection.
NOTE
Spare parts – If a part needs replacement, you MUST only use parts that meet the
manufacturer's part number specifications.
Replacement parts that DO NOT meet specifications may result in a safety hazard or
poor operation of the generator and will VOID the warranty.
Major servicing including installation or replacement parts, should be made by a
qualified service technician.
Item
Maintenance
Check Level
Engine Oil
Air Filter
Check/Adjust
Spark Plug
Replace
Valve
Check/Adjust
Clearance
Combustion
Chamber
Fuel Tank &
Filter
Fuel Line
* Service more frequently in dusty environments.
** Work to be carried out by a qualified engineer or your service dealer.
Every
Usage
X
Change
Check
X
Clean
Clean
Clean
Clean
st
1
month
Every 3
or 20
months or
hours
50 hours
X
X*
After every 300 hrs**
Every 2 years, replace if necessary**
17
Every 6
Every 12
months or
month or
100 hours
200 hours
X
X
X
X**
X**

Hide quick links:

Advertisement

Table of Contents
loading