Basics and mounting
Wiring > Wiring power modules

2.5.3 Wiring power modules

Terminal module terminals
Data
22
3.
Attach the cables with the accordingly stripped cable screen and fix it by the shield
clamp with the shield bus.
Power modules are either integrated to the head module or may be installed between the
periphery modules. With power modules, terminals with spring clamp technology are
used for wiring. The spring clamp technology allows quick and easy connection of your
signal and supply lines. In contrast to screw terminal connections this type of connection
is vibration proof.
U
30V DC
max
I
10A
max
Cross section
0.08 ... 1.5mm
Stripping length 10mm
2
(AWG 28 ... 16)
HB300 | IM | 053-1ML00 | en | 18-42