2.3 Operation elements and terminal layout on the board

„Door open"
button
„Door closed"
button
DIP
Switch
Figure 2-1 Operation elements and connector layout
Service buttons „Door open" and „Door closed":
Using both service buttons „Door open" and „Door closed" the door can be moved in both directions.
The motion is being performed as long as the button is pressed.
DIP-Switch
DIP 1 : Basic data setting
A setting which decides whether basic parameters for an one-sided (DIP 1 off) or middle-opening
(DIP 1 on) door are loaded into the main memory during estimation of door width.
DIP 2: Door width determination
The mechanical door width is determined using the door width determination function and it is
stored in the control system.
10/2015
Transducer inputs
4 – 0V
3 – 24 V DC
2 – Channel B
1 – Channel A
Signal inputs
6 – 0V DC
5 – 24V DC max 10 mA
4 – Reversing (light barrier)
3 – Pushing
2 – Closing
1 – Opening
Status outputs
9 – No
8 – com Door reversed
7 – NC_____________
6 – NO
Door is
5 – com closed
4 – NC_____________
3 – NO
2 – com Door is opened
1 - NC
Power supply
3 – Protecting cable
2 – N
1 – L
(pre-cabled)