ETG LDO AC 3.0 Installation And Operation Manual page 17

Door drive
Table of Contents

Advertisement

Navigation button
Forward button
Backward button
ENTER button
START button
STOP/RESET
button
The „Stop/Reset" button is an emergency switch for the converter. Pressing the button causes the
program for door motion to come to an end. After pressing the button, the plug must be pulled out
from the socket and the program has to be restarted. The „Run" button is available for the converter,
but not for the door program. After a power outage, the door control system must obtain a
closed" signal in order to determine the door position.
Course of configuration
During configuration setting, no control signals of the elevator control must be present. If
!
necessary, the CN2 connector must be disconnected.
-
select the desired parameter using the navigation buttons and select the exact parameter
value using plus and minus buttons
(parameter overview, see table 5.1, confgurable parameters15)
-
pressing the Enter button causes the cinfigured value to be displayed
-
change the value using both green arrow buttons
-
confirm the changed value using the Enter button
-
move the doors using both service buttons "Door open" and "Door close", and test the
change
-
Connect the CN2 connector again (when necessary)
If the A021 and/or A022 parameters are going to be increased, the P065 and /or P064
parameter must be increased before!!!
The maximum static closing force of 150 N should not be exceeded.
10/2015
Moves to the first parameter in the next group (function mode)
Cancels parameter change
Moves the cursor one digit to the right (digit input mode)
Pressing and holding the button for 1s results in return to d001 parameter
This button enables parameter changing or selection (increasing values). If the
Backward button is pressed simultaneously, digit input mode is started.
This button enables parameter changing or selection (increasing values). If the
Forward button is pressed simultaneously, digit input mode is started.
Moves from parameter number to parameter contents
Saves modified parameter and returns to parameter number
Moves the cursor one digit to the left (digit input mode)
This button causes the frequency converter to start execution of
corresponding program
This button causes the frequency converter to stop execution of
corresponding program and resets potential errors