3 Technical Data

Total
permissible door leaf
permissible door width
permissible operating temperature
Housing
execution
Housing cover lock
Protection type
Protection class
Dimensions
Control
Power supply
Control inputs CN2/1-4
Control outputs CN2/5
Terminals
Alternating current-Asynchronous motor-Drive motor
Protection type
Power supply
Rated current
Power
Rated frequency
Mass
Output
Toothed profile width:
Numer of teeth:
Transducer
Incremental transducer
technology
Protection type:
Power supply voltage:
10/2015
max. 200 kg in case of Type 200
max. 420 kg in case of Type 420
max.
4000
mm
max. 60 °C min. -10 °C
zinc-plated, installed on a foot,
1 pc. Phillips screw M4
IP
23
1
W/H/D 195mm/175mm/120mm
1 x 230 V AC -15% / +10%; 50 Hz ±5%
+ 18 V to + 27 V DC; 5 mA per input
24 V DC, 0,02A
Sockets (Phönix)
IP 55
230 V Delta connection
0,88 A Delta connection, Type 200
1.19 A Delta connection, Type 420
0,12 kW for Type 200; 0.18 kW for Type 420
50 Hz
4,5 kg
Toothed belt pulley
15 mm
24
Angular momentum transducer with contactless sensor
IP 65
+24 V DC ±5%
Page 10 of 24