Maintenance of the roof air conditioner
Interval
Inspection/maintenance
Regularly
Check the condensation water drainage:
➤ Check whether the condensation water drainage channels
Clean the filter of the air discharge unit (fig. 0, page 35):
Regularly
➤ Manually take off the filter cover (1).
➤ Remove the filter (2).
➤ Clean the filter (2) with a detergent solution and let it dry.
➤ Put the dry filter (2) back in.
➤ Put the cover (1) back on.
Once per year
Check the profile seals:
➤ Check the seal between the roof air conditioner and the roof of the
Once per year
Have the heat exchanger serviced:
➤ Have the heat exchanger of the roof air conditioner serviced by
Replace the carbon filter (fig. 0, page 35):
Once per year
➤ Manually take off the filter cover (1).
➤ Remove the filter (2).
➤ Remove the carbon filter (3).
➤ Clean the filter (2) with a detergent solution and let it dry.
➤ Put a new carbon filter in.
➤ Put the dry filter (2) back in.
➤ Put the cover (1) back on.
36
(fig. 9 1page 35) at the sides of the roof air conditioner are clear
and the condensation water is able to escape.
vehicle for cracks and other damage.
specialist workshop.
FreshJet
EN