Technical Data - Dometic FJ 2200 Operating Manual

Hide thumbs Also See for FJ 2200:
Table of Contents

Advertisement

FreshJet
14

Technical data

Ref. no.:
Compressor cooling capacity:
Cooling capacity based on
ISO 5151:
Heating capacity:
Rated input voltage:
Power consumption in cooling
mode:
Power consumption in heating
mode:
Operating temperature range:
Refrigerant:
Refrigerant quantity:
CO
equivalent:
2
Global warming potential
(GWP):
Blower:
Protection class:
Max. volume of space in the
vehicle (with insulated walls):
Dimensions L x W x H:
Weight:
Inspection/certification:
Contains fluorinated greenhouse gases
Hermetically sealed equipment
EN
FreshJet 2200
9105306512
2200 W
1800 W
1200 W
230 Vw / 50 Hz
4.1 A
5.2 A
0 °C to +52 °C
R-407c
520 g
0.92248 t
1774
4 blower levels
1 Automatic mode
IPX4
25 m³
fig. a, page 42
approx. 32 kg
Technical data
FreshJet 3200
9105306660
3000 W
2600 W
2400 W
6.3 A
5.6 A
R-410a
735 g
1.53468 t
2088
29 m³
fig. b, page 42
approx. 37 kg