Create A Voice Vlan - TRENDnet TEG-S80ES User Manual

8-port gigabit edgesmart switch
Table of Contents

Advertisement

TRENDnet User's Guide
If the IP phone(s) that you are installing cannot be configured with a VLAN ID, then the
switch ports should be configured as Static tagged ports within the voice VLAN.
Note: Link Layer Discovery Protocol for Media Endpoint Devices (LLDP- MED) is not
supported on the switch. Each IP phone that is VLAN aware should be manually
configured for the VLAN ID that matches your voice VLAN ID. Each of the voice VLAN
ports connected to an IP phone should be configured as "Not Member" ports of the
tagged VLAN.

Create a Voice VLAN

Network > Voice VLAN > Settings
Note: Prior to configuring your voice VLAN, you must first configure a tagged VLAN. This
VLAN will be used as a basis for your voice VLAN.
1. Log into your switch management page (see
on page 7).
2. Click on Network, click on Voice VLAN, and click on Settings.
3. Review the settings.
Use the following procedure to configure voice VLAN:
From the Voice VLAN field at the top of the page, select one of the following
radio button choices:
o
Enable - The voice VLAN feature is active. The other parameter fields
in the voice VLAN Global Settings section become active and are
eligible for data to be entered.
o
Disable - The voice VLAN feature is inactive. The other parameter
fields in the voice VLAN Global Settings section become inactive and
are greyed out so that data cannot be entered.
In the Voice VLAN Global Settings section, enter the configuration information
for the following parameters:
o
VLAN ID - This parameter is the tagged VLAN ID that has been
configured in "Tagged VLAN Configuration". It is a pull-down menu
showing the tagged VLAN IDs that have been defined.
© Copyright 2018 TRENDnet. All Rights Reserved.
"Access your switch management
page"
o
CoS - This parameter is CoS priority level assigned to the voice data
packets received on each voice VLAN port. For the COS priority to be
effective, QoS must be Enabled.
Click Apply to save the settings.
NOTE: The configured settings are only applied to the switch's temporary memory and
will be lost upon the next power-cycle. Please follow these next steps to save the
configurations to the switch's NV-RAM to ensure the settings will remain throughout
power-cycles and reboots:
1. From the menu on the left: click on Save, then click the blue button Save
Settings to Flash.
TEG-S80ES
38

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents