ABB -free@home TH-1.1 Product Manual page 13

Hide thumbs Also See for ABB-free@home TH-1.1:
Table of Contents

Advertisement

Setting
Description
Limits how often
compressor for stage
2 cooling will be
switched ON.
Max.
Limiting compressor
compressor
cycles saves energy
cycles per
and reduces wear.
nd
hour, 2
Stage 2 is controlled
stage
by Y2. Compressor
is part of air-
conditioning or heat
pump.
Limits how often
compressor for stage
1 heating will switch
ON. Limiting
compressor cycles
Max. heating
saves energy and
cycles per
reduces wear. Stage
st
hour, 1
stage
1 heat is controlled
by Y1. Compressor
is part of air-
conditioner or heat
pump.
Limits how often
compressor for stage
2 heating will be
switched ON.
Max. heating
Limiting compressor
cycles per
cycles saves energy
nd
hour, 2
and reduces wear.
stage
Stage 2 heat is
controlled by Y2.
Compressor is part
of air-conditioner or
heat pump.
Defines desired
humidity percentage
Humidity
when running a
setpoint [%]
humidifier or
dehumidifier.
Note: Setting
depends on type of
equipment.
Thermostat-
controlled is safest
option. Select when
HVAC equipment
does not control fan
or if user is unsure.
Fan control
Equipment-controlled
is more common.
Note: User must
validate system
equipment has
control over fan. If
not, HVAC may
overheat/freeze as it
relies on being
Product Manual 2CQA 100 014 B0001 │ 2018-09-28
Options
1 to 6
in increments of 1
1 to 12
in increments of 1
1 to 12
in increments of 1
20 to 80 in
increments of 10
· Thermostat-
controlled
· Equipment-
controlled
Configuring the Thermostat
Image
│13

Advertisement

Table of Contents
loading

Table of Contents