ABB -free@home TH-1.1 Product Manual page 10

Hide thumbs Also See for ABB-free@home TH-1.1:
Table of Contents

Advertisement

Setting
Description
Note: Only if air-
conditioner or heat
pump exists.
Compressor
Setting defines
delay between
minimum time
cycles [s]
system must wait
before air-conditioner
or heat pump can
run again.
Note: Not for water-
based systems.
Defines fan-running
Fan timer
time after heating
after heating
has switched off.
[s]
During time
remaining heat in
system is extracted.
Note: Not for water-
based systems.
Defines fan-running
time after air
Fan timer
conditioning has
after cooling
switched OFF. This
[s]
allows system to
distribute remaining
pre-cooled air
already present in
ducts.
Note: Only for gas
furnaces.
Setting defines
minimum time gas
furnace stays ON.
Minimum ON
Some gas furnaces
time for gas
should not be
furnace [s]
switched ON/OFF
rapidly to prevent
damage or
premature wear of
parts.
Note: Not for water-
based systems.
Delays time for fan
Fan delay ON
after cooling starts.
cooling [s]
Prevents warm air
coming out of vent
while air conditioning
is still cooling.
Product Manual 2CQA 100 014 B0001 │ 2018-09-28
Options
·
Manual (active
open)
·
Manual (active
closed)
120 to 360
in increments of 10
60 to 240
in increments of 10
60 to 240
in increments of 10
0 to 240
in increments of 10
0 to 240
in increments of 10
Configuring the Thermostat
Image
│10