The following directives and standards must be complied with when planning, setting up, and
maintaining grid-connected PV systems:
EU-STANDARDS
EUROCODE 1 (EN 1991-1)
Actions on structures
EN 13501
Fire behavior of building materials and buil-
ding component
EN 60728-11
Setting up and operating (grounding) aerial
systems
EN 62305
Lightning protection
EN 62446
Grid-coupled photovoltaic systems
IEC 60364
Erection of low-voltage systems
VISION 60M STYLE
VISION 60P STYLE
VDE-DIRECTIVES
VDE 0100
Erection of low-voltage systems
VDE 0105-100
Operation of electrical systems
EXCLUSION OF LIABILITY
The warranty terms available at
www.solarwatt.com apply.
VDE-TEST MARK
You can check the current status of the instal-
lation instructions at www.solarwatt.com.
Please find other languages at
www.solarwatt.com.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VISION 60M HIGH POWER and is the answer not in the manual?

Questions and answers

Summary of Contents for solarwatt VISION 60M HIGH POWER

  • Page 1: Installation Instructions

    SOLARWATT FRAMED GLASS-GLASS MODULES | INSTALLATION INSTRUCTIONS | EN SOLARWATT INSTALLATION INSTRUCTIONS FOR FRAMED GLASS-GLASS MODULES VISION 60M HIGH POWER VISION 60M STYLE VISION 60P VISION 60P STYLE The following directives and standards must be complied with when planning, setting up, and...
  • Page 2: Information On The Solar Module

    41.8°)] can also be found on the beyond the current valid standards and enable nameplate of the solar module. PAGE 18 | SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017...
  • Page 3: Transport And Storage

    Furthermore, the use of the products on mobile units such as vehicles or ships is not permitted. SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017 | PAGE 19...
  • Page 4 (EN 1991-1). additional loads in the event of snow over- hang or build-up to reflect the actual loads PAGE 20 | SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017...
  • Page 5 Fastening on short sides The maximum pressure load to the solar module for the installation method is 3,000 N/m². areas approved for fastening substructure SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017 | PAGE 21...
  • Page 6 The maximum pressure load to the solar module for the installation method is 4,200 N/m². substructure 245 ± 5 mm 245 ± 5 mm PAGE 22 | SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017...
  • Page 7 Fastening on long sides The maximum pressure load to the solar module for the installation method is 5,500 N/m². areas approved for fastening substructure SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017 | PAGE 23...
  • Page 8 The maximum pressure load to the solar mo- dule for the installation method is 2,400 N/m². areas approved for fastening substructure PAGE 24 | SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017...
  • Page 9: Electrical Connection And Grounding

    Connection of modules in series is only per- reverse current feed and only use standardi- mitted up to the maximum system voltage as zed photovoltaic cables (recommendation: at SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017 | PAGE 25...
  • Page 10 The plug contacts must not be connected or disconnected under load. Failure to comply with this warning could result in DEATH! PAGE 26 | SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017...
  • Page 11: Maintenance And Servicing

    The WEEE Directive is nationally oriented, meaning that each EU SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017 | PAGE 27...
  • Page 12 SOLARWATT the guaranteed output of the Solar Modules is at least 87% of the nominal output on the Solar PAGE 28 | SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017...
  • Page 13 End Customer a flat rate payment of € 150.00 structions in the assembly manual, per system (i.e. photovoltaic system with a single being improperly modified by the End SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017 | PAGE 29...
  • Page 14 SOLARWATT upon request the End Customer can regularly and fully expect PAGE 30 | SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017...
  • Page 15 If any individual provisions of these Warranty Condi-tions are or become invalid, the validity of the remaining provisions remains unaffected. SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017 | PAGE 31...
  • Page 16 SOLARWATT GmbH | Maria-Reiche-Str. 2a | 01109 Dresden | Germany Tel. + 49 351 8895-0 | Fax + 49 351 8895-100 | info@solarwatt.com Certified in accordance with ISO 9001 and ISO 14001| BS OHSAS 18001:2007...

This manual is also suitable for:

Vision 60m styleVision 60pVision 60p style

Table of Contents