The following directives and standards must be complied with when planning, setting up, and
maintaining grid-connected PV systems:
EU-STANDARDS
EUROCODE 1 (EN 1991-1)
Actions on structures
EN 13501
Fire behavior of building materials and buil-
ding component
EN 60728-11
Setting up and operating (grounding) aerial
systems
EN 62305
Lightning protection
EN 62446
Grid-coupled photovoltaic systems
IEC 60364
Erection of low-voltage systems
VISION 60M STYLE
VISION 60P STYLE
VDE-DIRECTIVES
VDE 0100
Erection of low-voltage systems
VDE 0105-100
Operation of electrical systems
EXCLUSION OF LIABILITY
The warranty terms available at
www.solarwatt.com apply.
VDE-TEST MARK
You can check the current status of the instal-
lation instructions at www.solarwatt.com.
Please find other languages at
www.solarwatt.com.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the VISION 60M HIGH POWER and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for solarwatt VISION 60M HIGH POWER

  • Page 1: Installation Instructions

    SOLARWATT FRAMED GLASS-GLASS MODULES | INSTALLATION INSTRUCTIONS | EN SOLARWATT INSTALLATION INSTRUCTIONS FOR FRAMED GLASS-GLASS MODULES VISION 60M HIGH POWER VISION 60M STYLE VISION 60P VISION 60P STYLE The following directives and standards must be complied with when planning, setting up, and...
  • Page 2: Information On The Solar Module

    41.8°)] can also be found on the beyond the current valid standards and enable nameplate of the solar module. PAGE 18 | SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017...
  • Page 3: Transport And Storage

    Furthermore, the use of the products on mobile units such as vehicles or ships is not permitted. SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017 | PAGE 19...
  • Page 4 (EN 1991-1). additional loads in the event of snow over- hang or build-up to reflect the actual loads PAGE 20 | SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017...
  • Page 5 Fastening on short sides The maximum pressure load to the solar module for the installation method is 3,000 N/m². areas approved for fastening substructure SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017 | PAGE 21...
  • Page 6 The maximum pressure load to the solar module for the installation method is 4,200 N/m². substructure 245 ± 5 mm 245 ± 5 mm PAGE 22 | SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017...
  • Page 7 Fastening on long sides The maximum pressure load to the solar module for the installation method is 5,500 N/m². areas approved for fastening substructure SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017 | PAGE 23...
  • Page 8 The maximum pressure load to the solar mo- dule for the installation method is 2,400 N/m². areas approved for fastening substructure PAGE 24 | SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017...
  • Page 9: Electrical Connection And Grounding

    Connection of modules in series is only per- reverse current feed and only use standardi- mitted up to the maximum system voltage as zed photovoltaic cables (recommendation: at SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017 | PAGE 25...
  • Page 10 The plug contacts must not be connected or disconnected under load. Failure to comply with this warning could result in DEATH! PAGE 26 | SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017...
  • Page 11: Maintenance And Servicing

    The WEEE Directive is nationally oriented, meaning that each EU SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017 | PAGE 27...
  • Page 12 SOLARWATT the guaranteed output of the Solar Modules is at least 87% of the nominal output on the Solar PAGE 28 | SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017...
  • Page 13 End Customer a flat rate payment of € 150.00 structions in the assembly manual, per system (i.e. photovoltaic system with a single being improperly modified by the End SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017 | PAGE 29...
  • Page 14 SOLARWATT upon request the End Customer can regularly and fully expect PAGE 30 | SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017...
  • Page 15 If any individual provisions of these Warranty Condi-tions are or become invalid, the validity of the remaining provisions remains unaffected. SUBJECT TO CHANGE | © 2017 SOLARWATT GMBH | AZ-TM-PMS-0673 | REV 012 | STATUS: 08/2017 | PAGE 31...
  • Page 16 SOLARWATT GmbH | Maria-Reiche-Str. 2a | 01109 Dresden | Germany Tel. + 49 351 8895-0 | Fax + 49 351 8895-100 | info@solarwatt.com Certified in accordance with ISO 9001 and ISO 14001| BS OHSAS 18001:2007...

This manual is also suitable for:

Vision 60m styleVision 60pVision 60p style

Table of Contents