Advertisement

sOlARWAtt
instAllAtiOn instRuctiOns
f OR fRAMeD glAss-fOil sOlAR MODules
SOLARWATT BLUE 60P
The following directives and standards must be complied with when planning, setting up, and maintaining grid-
connected PV systems:
eu-stAnDARDs
EUROCODE 1 (EN 1991-1)
Actions on structures
EN 13501
Fire behavior of building materials and building
component
EN 60728-11
Setting up and operating (grounding) aerial systems
EN 62305
Lightning protection
EN 62446
Grid-coupled photovoltaic systems
IEC 60364
Erection of low-voltage systems
solarwatt installation instruCtions | en
VDe-DiRectiVes
VDE 0100
Erection of low-voltage systems
VDE 0105-100
Operation of electrical systems
eXclusiOn Of liABilitY
The warranty terms available at
www.solarwatt.net apply.
VDe test MARK
cOntents
Information for complaints
You can check the current status of
the installation instructions at www.
solarwatt.net.
Weitere Sprachversionen finden
Sie unter www.solarwatt.net.
Please find other languages at
www.solarwatt.net.
P.10
P.11
P.14
P.16
P.16
P.16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the BLUE 60P and is the answer not in the manual?

Questions and answers

Summary of Contents for solarwatt BLUE 60P

  • Page 1: Table Of Contents

    | en sOlARWAtt instAllAtiOn instRuctiOns f OR fRAMeD glAss-fOil sOlAR MODules SOLARWATT BLUE 60P The following directives and standards must be complied with when planning, setting up, and maintaining grid- cOntents connected PV systems: eu-stAnDARDs VDe-DiRectiVes EUROCODE 1 (EN 1991-1)
  • Page 2: Information On The Solar Module

    If more than 33 % solar modules on one pallet are damaged, refuse to accept the pallet. Please fill out the „Transport Damage Complaint Notification“ form (www. solarwatt.net) and return it to SOLARWATT GmbH. Subject to change | © 2016 SOLARWATT GmbH | AZ-TM-PMS-0973 | Rev 008 | Status: 11/2016...
  • Page 3: Installation

    The solar module heats up during operation. Ensure that there is sufficient rear ven- tilation to avoid reductions in yield. Also ensure that no flammable gases can escape or accumulate close by. Subject to change | © 2016 SOLARWATT GmbH | AZ-TM-PMS-0973 | Rev 008 | Status: 11/2016...
  • Page 4 2,400 N/m². ule for the installation method is 2,400 N/m². 100 mm 100 mm areas approved for fastening Subject to change | © 2016 SOLARWATT GmbH | AZ-TM-PMS-0973 | Rev 008 | Status: 11/2016...
  • Page 5 The maximum pressure load to the solar module for the installation method is 3,500 N/m². nOte It is not permitted to use SOLARWATT solar modules as overhead glazing. For roof installation, these solar modules may only be installed over a fi re-resistant roof covering. inseRtiOn sYsteM...
  • Page 6: Electrical Connection And Grounding

    A system with multiple solar modules can generate life-threatening voltages and electrical currents. Do not touch the electrical connections or cable ends while the solar module is exposed to light. Subject to change | © 2016 SOLARWATT GmbH | AZ-TM-PMS-0973 | Rev 008 | Status: 11/2016...
  • Page 7 For this, take into Failure to comply with this warning account the relevant valid regulations (e.g. EN 62305 and VDE 100). could result in DEATH! Subject to change | © 2016 SOLARWATT GmbH | AZ-TM-PMS-0973 | Rev 008 | Status: 11/2016...
  • Page 8: Maintenance And Servicing

    SOLARWATT GmbH | Maria-Reiche-Str. 2a | 01109 Dresden | Germany Tel. + 49 351 8895-0 | Fax + 49 351 8895-111 | info@solarwatt.net Certified in accordance with ISO 9001 and ISO 14001| BS OHSAS 18001:2007...