Location; Cleaning / Disinfection - Dometic UF 755G Operating Instructions Manual

Table of Contents

Advertisement

Installation
L L o o c c a a t t i i o o n n
• The unit is intended for indoor use only. It must be set up in a dry well-
ventilated place where no conductive pollution occurs.
(POLLUTION DEGREE 1).
• The altitude of the location must not exceed 10000ft.
• Avoid direct sunlight or locating it close to a heat
source. The ambient temperature of the location
should be 41°F to 104°F. The relative humidity
must not exceed 70% up to 88°F, decreasing
linearly to 50% at 104°F.
• Ensure that the unit is steady and perfectly
straight and does not knock against any of the
units next to it.
• The air must be allowed to circulate freely all
round the unit as good air circulation is essential
for trouble-free operation. There must always be
a free space of at least 3 inches all round the
unit. The clearance to the ceiling for upright units
must be at least 20 inches.
• Do not locate the unit below a ceiling fan or right
next to air-conditioning equipment.
• Net weigth (without load) : UF455G - 441 lbs /
UF755G - 507 lbs.
• The unit is fitted with castors. Once it is in its
final location, the feet must be unscrewed to
immobilise it and stop it rolling away. Unscrew
the foot until it touches the floor and then screw
the lock nut back up.
• The door handle has been turned by 90° at the
factory end to facilitate packaging and
transporting, and should be turned during
installation in accordance with the diagram.
C C l l e e a a n n i i n n g g / / D D i i s s i i n n f f e e c c t t i i o o n n
• Clean or disinfect the unit inside and outside
before using it. Use only gentle cleaning agents.
Never use aggressive or caustic cleaning agents,
scouring powder, steel wool, abrasive sponges or
chemical solvents.
!
min 70 mm
POWER FAIL
ALARM HISTORY
POWER FAIL
ALARM HISTORY
O
I
ENTER
O
I
ENTER
ALARM TEST
ALARM TEST
min 70 mm
min 3 inches
min 70 mm
min 70 mm
POWER FAIL
ALARM HISTORY
POWER FAIL
ALARM HISTORY
O
I
ENTER
O
I
ENTER
ALARM TEST
ALARM TEST
POWER FAIL
ALARM HISTORY
POWER FAIL
ALARM HISTORY
O
I
O
I
ENTER
ALARM TEST
ENTER
ALARM TEST
• For disinfecting, we recommend all the surface
disinfecting agents commonly used by the
customer, provided they are recommended by the
German Association for Hygiene and Microbiology
(DGHM) or other national organisations. For
disinfecting small areas, we recommend using a
concentrated alcoholic agent.
POWER FAIL
ALARM HISTORY
O
I
ENTER
ALARM TEST
min 70 mm
min 3 inches
min 70 mm
lock nut
foot
1
4
3
2
POW
O
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Uf 455g

Table of Contents