Installation

Grounding

The equipment must be grounded to reduce the risk
of static sparking. Static sparking can cause fumes to
ignite or explode. Grounding provides an escape wire
for the electric current.
Pump: the displacement pump is grounded with a wire
connecting the pump to the control enclosure. Locate
the small hole (W) in the pump outlet housing. Attach
the ground wire (Y) to the pump outlet housing using the
ground screw (X) supplied with your system. Tighten the
ground screw securely. Do not operate the equipment
without the ground wire in place.
Air compressor: follow manufacturer's recommenda-
tions.
Fluid supply container: follow local code.
Object being dispensed: follow local code.
F
. 2: Attach Grounding Wire
IG
334127D

Connect to a Graco Air Motor

The displacement pump may be installed on Senator,
®
Bulldog, King
, and NXT air motors using Tie Rod Kits.
See the following kit manuals for installation instruc-
tions.
Manual
Tie Rod Kit
334131
24V752
334132
24V754
Installation
Air Motor
Bulldog
Senator
King
NXT