  • Page 1 Operator’s Manual Please read the operator’s manual carefully and make sure you understand the instructions before using the machine.
  • Page 2 0360-89001-02...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Topic Section Introduction Design And Features iQ1014S General Safety Personal Protective Equipment General Safety Precautions Work Area Safety Machine Use And Care Electrical Requirements Symbols On The Machine Explanation Of Warning Levels Safety Messages Transport, Set up & Operation...
  • Page 4: Introduction

    INTRODUCTION Dear Customer The Manufacturer’s Reservation We at IQ Power Tools™ want to congratulate you on Subsequent to publishing this manual, IQ Power Tools selecting the iQ1014S® Heavy Duty Dust Collector may issue additional information for safe operation of with 14” iQ Masonry Saw. We are certain that you will this product.
  • Page 5: General Safety

    • Hair covering or devices to contain long hair qualified specialists. See instructions under the heading i.e.: Hair Ties For Guys Maintenance. Always use genuine accessories. Contact your dealer for more information. 888-274-7744 iQ1014S www.iqpowertools.com Operator’s Manual...
  • Page 6: Work Area Safety

    If plunge function is used, place one hand on service agent or an experienced user. Do not attempt any the cutting handle. task or operation that makes you feel unsure whether or not it is safe. iQ1014S 888-274-7744 Operator’s Manual www.iqpowertools.com...
  • Page 7 Do not modify the plug. If it will not fit the outlet have a proper outlet installed by a qualified electrician. Make sure local regulations and ordinances are followed. 888-274-7744 iQ1014S www.iqpowertools.com Operator’s Manual...
  • Page 8: Symbols On The Machine

    Do not force a tool or an attachment, to do a job that it COULD lead to DEATH or was not designed to do. SERIOUS INJURY. Not following instructions NEVER CUT MAGNESIUM WITH THIS TOOL CAN lead to injury. iQ1014S 888-274-7744 Operator’s Manual www.iqpowertools.com...
  • Page 9: Safety Messages

    Check for broken parts and mountings and all other The iQ1014S® is very effective dust collector but, your conditions that may affect the operation if the power risk from these exposures varies depending on how tool.
  • Page 10: Transport, Setup & Operation

    Always observe safe lifting practices when lifting the iQ1014S. PRE-START INSPECTION: The pre-start inspection should be performed before The iQ1014S is designed to be pushed by the handle at beginning any job. the back of the machine. Setup If the diamond blade shows signs of fatigue cracking, replace the blade before starting work.
  • Page 11: Maintenance

    To empty the dust tray open access door on the front of unit remove tray and dispose of debris. Dust tray should be checked periodically and debris removed regularly. Always wear personal protective equipment when servicing unit. 888-274-7744 iQ1014S www.iqpowertools.com Operator’s Manual...
  • Page 12: Blades

    CUTTING CAPACITY: 1. Push in blade lock button (L) and rotate wheel (J) by The iQ1014S® provides a cutting capacity of pieces that hand until blade lock button engages slot in inside flange are 4.5” Height Maximum –12” Long Maximum.
  • Page 13 NOTE: Unit may be converted to a 3-wire twist lock cord set at an authorized service center. LUBRICATION: Closed –type, grease-sealed ball bearings are used throughout. These bearings have sufficient lubrication packed in them at the factory to last the life of the machine. 888-274-7744 iQ1014S www.iqpowertools.com Operator’s Manual...
  • Page 14: Carbon Brushes

    Untighten carbon brush retainer cap with standard screwdriver. Install carbon brush making sure to align tabs into slots. Remove carbon brush retainer cap. Tighten carbon brush retainer cap to secure. Remove carbon brush. iQ1014S 888-274-7744 Operator’s Manual www.iqpowertools.com...
  • Page 15: Controller

    The motor controller heat sink temperature Drive overheat is over maximum limit. If error code blinks more than 6 times, please call service technician for assistance. Indicator Key: Green light: Power On Red Light: Error, blinking time codes 888-274-7744 iQ1014S www.iqpowertools.com Operator’s Manual...
  • Page 16: Technical Data

    TECHNICAL DATA SAW MOTOR IQ1014S POWER, AMPS INPUT VOLTAGE, V 220-240 PHASES BLADE SPEED, RPM 3700 VACUUM MOTOR POWER, AMPS MAX STATIC PRESSURE 12 INCH H 1000 CUTTING EQUIPMENT BLADE SIZE - MAX, INCH/MM 14 / 355 SAW DEPTH - MAX, INCH/MM 4.5 / 114...
  • Page 17 The new iQ1014 S® Dust Control Chop Saw sold Parts and labor needed to maintain products, by iQ Power Tools or an iQ authorized dealer is and the replacement of components due to normal warranted to be free from manufacturing defects wear and tear, are the purchaser’s responsibility...
  • Page 18 NOTES iQ1014S 888-274-7744 Operator’s Manual www.iqpowertools.com...