Titon TIFC100HT Installation Manual

Titon TIFC100HT Installation Manual

Tifc - centrifugal fan

Advertisement

Quick Links

G
Installation manual
TIFC - Centrifugal fan
Read this manual carefully before using the product and keep
it in a safe place for reference. This product was constructed
up to standard and in compliance with regulations relating to
electrical equipment and must be installed by technically
qualified personnel.
The manufacturer assumes no responsibility for damage to
persons or property resulting from failure to observe the
regulations contained in this booklet.
PRECAUTIONS FOR INSTALLATION, USE AND MAINTENANCE
• The device should not be used for applications other than those specified in this manual.
• After removing the product from its packaging, verify its condition. In case of doubt,
contact a qualified technician. Do not leave packaging within the reach of small children
or people with disabilities.
• Do not touch the appliance with wet or damp hands/feet.
• This appliance can be used by children aged from 8 years and above and persons with
reduced physical, sensory or mental capabilities or lack of experience and knowledge
if they have been given supervision or instruction concerning use of the appliance
in a safe way and understand the hazards involved. Children shall not play with the
appliance. Cleaning and user maintenance shall not be made by children without
supervision.
• Do not use the product in the presence of flammable vapours, such as alcohol,
insecticides, gasoline, etc.
• If any abnormalities in operation are detected, disconnect the device from the mains supply
and contact a qualified technician immediately. Use original spare parts only for repairs.
• The electrical system to which the device is connected must comply with regulations.
• Before connecting the product to the power supply or the power outlet, ensure that:
- the data plate (voltage and frequency) correspond to those of the electrical mains
- the electrical power supply/socket is adequate for maximum device power. If not,
contact a qualified technician.
• The device should not be used as an activator for water heaters, stoves, etc., nor
should it discharge into hot air/fume vent ducts deriving from any type of combustion
unit. It must expel air outside via its own special duct.
• Operating temperature: 0°C up to +50°C.
• The device is designed to extract clean air only, i.e. without grease, soot, chemical or
corrosive agents, or flammable or explosive mixtures.
• Do not leave the device exposed to atmospheric agents (rain, sun, snow, etc.).
• Do not immerse the device or its parts in water or other liquids.
• Turn off the main switch whenever a malfunction is detected or when cleaning.
• For installation an omnipolar switch should be incorporated in the fixed wiring, in
accordance with the wiring regulations, to provide a full disconnection under overvoltage
category III conditions (contact opening distance equal to or greater than 3mm).
• If the supply cord is damaged, it must be replaced by the manufacturer, its service
agent or similarly qualified persons in order to avoid a hazard.
Fig. 1
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TIFC100HT and is the answer not in the manual?

Questions and answers

Summary of Contents for Titon TIFC100HT

  • Page 1 Installation manual TIFC - Centrifugal fan Read this manual carefully before using the product and keep it in a safe place for reference. This product was constructed up to standard and in compliance with regulations relating to electrical equipment and must be installed by technically qualified personnel.
  • Page 2: Technical Specifications

    • Motor mounted on ball bearings that guarantee a longer product life cycle (30,000h) and suitable for cold climates. • The fan is double insulated: no earth connection is required. • Suitable for continuous or intermittent operation. • IPX4 degree of protection. • Power supply 220V to 240V~ 50/60Hz. Airflow Static pressure Power Sound pressure Model /h max Pa max W max dB(A) @3m TIFC100HT 104/62 251/142 28/17 38/27 VERSIONS WITH HUMIDISTAT & TIMER The fan is equipped with a humidity detector, whose threshold is adjustable from 50% to 95% Relative Humidity, and with a timer which is adjustable from aprox. 1 minute to 25 minutes via corresponding trimmer (Fig. 48B). Turn the trimmer HY completely clockwise and the humidistat function is deactivated. Automatic humidistat operation: connected according to the diagram in Fig. 47C, when...
  • Page 3 the percentage of Relative Humidity exceeds the pre-set intervention threshold, the fan starts up automatically. When the percentage of Relative Humidity goes below the threshold, the fan continues to function for a pre-set period of time. Operation with switch connection: connected according to the diagram in Fig. 47C, after the light is switched on, the fan activates with a delay of aprox. 1.5 seconds. After it is switched off, the fan continues to function for a pre-set period of time. Attention: when the relative humidity level is higher than the pre-set threshold, automatic operation with humidistat has priority over manual operation, or rather the fan cannot be stopped via switch. INSTALLATION (Fig. 2) perimetrical exhausting wall - surface wall - recessed ceiling - surface (accessory on demand) ceiling - recessed...
  • Page 4 MOUNTING TIFC100HT = Ø96mm...
  • Page 5 SURFACE CABLE H03VV-F ; H05VV-F 2 X 0,5 ÷ 1,5 mm BASE/STD 3 X 0,5 ÷ 1,5 mm 3 X 0,5 ÷ 1,5 mm T-HT 4 X 0,5 ÷ 1 mm 3 x Ø 5mm ~ 5mm ~ 150mm...
  • Page 6 RECESSED CABLE ENTRY H03VV-F ; H05VV-F 2 X 0,5 ÷ 1,5 mm BASE/STD 3 X 0,5 ÷ 1,5 mm 3 X 0,5 ÷ 1,5 mm T-HT 4 X 0,5 ÷ 1 mm 3 x Ø 5mm ~ 150mm...
  • Page 7 WIRING DIAGRAM: PAGE 11...
  • Page 8: Recessed Installation

    RECESSED INSTALLATION 233 mm RECESSED CABLE ENTRY H03VV-F ; H05VV-F 2 X 0,5 ÷ 1,5 mm BASE/STD 3 X 0,5 ÷ 1,5 mm 3 X 0,5 ÷ 1,5 mm T-HT 9÷40 mm 4 X 0,5 ÷ 1 mm...
  • Page 9 ~ 150mm...
  • Page 10 WIRING DIAGRAM: PAGE 11...
  • Page 11: Electrical Wiring

    ELECTRICAL WIRING TIFC100HT Vmax TIFC100HT Vmin TIMER MAINTENANCE / CLEANING...
  • Page 13 ErP Directive - Regulations 1253/2014 - 1254/2014 Mark TITON Model TIFC100HT SEC class SEC warm climates -7,7 kWh/m2.a SEC average climates -23,2 kWh/m2.a SEC cold climates -50,2 kWh/m2.a Energy label Unit typology Residential - unidirectional Type of drive multi-speed drive...
  • Page 14: Standard Conformity

    STANDARD CONFORMITY 2014/35/EU Low Voltage Directive (LVD) 2014/30/EU Electromagnetic Compatibility (EMC), in conformity with the following standards: Electrical Safety: EN60335-1(2012)+A11+A13; EN 60335-2-80(2003)+A1+A2. Electromagnetic Compatibility: EN 55014-1(2017); EN 55014-2(2015); EN 61000-3- 2(2014); EN 61000-3-3(2013). DISPOSAL AND RECYCLING Information on disposal of units at the end of life. This product complies with EU Directive 2002/96/EC. The symbol of the crossed-out dustbin indicates that this product must be collected separately from other waste at the end of its life. The user must, therefore, dispose of the product in question at suitable electronic and electro-technical waste disposal collection centres, or else send the product back to the retailer when purchasing a new, equivalent type device. Separate collection of decommissioned equipment for recycling, treatment and environmentally compatible disposal helps to prevent negative effects on the environment and on health and promotes the recycling of the materials that make up the equipment.
  • Page 15 NOTES...
  • Page 16 894 The Crescent, Colchester Business Park, Colchester, Essex, C04 9YQ, United Kingdom Tel: +44 (0)1206 814879 Fax: +44(0)1206 543126 Email: ventsales@titon.co.uk Web: www.titon.com 004072 - 00 - 0718...

Table of Contents