Summary of Contents for Titon HRV 1.3 Q Plus

  • Page 1 Manual HRV 1.3 Q Plus HRV 1.60 Q Plus HRV4 Q Plus HRV 1.35 Q Plus HRV 1.65 Q Plus HRV4.1 Q Plus HRV4.25 Q Plus HRV20 Q Plus H200 Q Plus H200 Q Plus ventilation systems...
  • Page 2: Important Information

    Warnings, Safety Information and Guidance Important Information Important: read these instructions fully before the installation of this appliance Installation of the appliance and accessories must be carried out by a quali- fied and suitable competent person and be carried out in clean, dry conditions where dust and humidity are at minimal levels.
  • Page 3 16. This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of ex- perience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
  • Page 4: Explanation Of Symbols On The Appliance

    Explanation of symbols on the appliance Symbol Definition Read instruction Manual. Risk of Electric Shock. General hazard safety alert. Wait until all machine components have completely stopped before touching them. Disconnect the mains supply before removing this cover. Disconnect the mains supply before removing this cover.
  • Page 5: Titon Recommend

    Titon Recommend: Any flexible ducting should only be used for final terminations only and must be a maximum of 300m long and be pulled taut, and straight. A minimum distance of 200mm between the HRV unit and any sharp bends in duct work.
  • Page 6: Table Of Contents

    Supply � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � � 22 Titon Recommend: � � � � � � � � � � � � � � � � � � � � � � � � � � � 5 auralite®...
  • Page 7: Units

    Units List of Products This Manual is for the following Products HRV1.3 TP473HMB H200 204x60 TP451HMB HRV1.35 TP408HMB H200 Ø150 TP452HMB HRV1.6 TP409HMB H200 Ø160 TP453HMB HRV1.6 TP410HMB HRV1.65 HE TP448HMB HRV20 HE TP652HMB HRV4 TP421HMB HRV4.1 TP422HMB HRV4.25 TP423HMB all with either suffix /544 or /RH When this document is viewed as a PDF the headings &...
  • Page 8: Product Information

    Product Information The HRVs are Mechanical Ventilation with Heat Recovery (MVHR) units. They are designed for the energy efficient ventilation of dwellings. The units are designed for continuous ventilation, exhausting stale moist air from bathrooms, toilets, kitchen and utility rooms. As the stale air is extracted, the unit’s heat exchanger transfers heat, which would have been wasted, to the fresh air being supplied to the bedrooms and living rooms.
  • Page 9: Units' Dimensions

    Units' Dimensions The following diagrams detail the overall size of the units, the duct port positions & the additional space required around the units (Service Void - - - -) to allow for commissioning and future service and maintenance. 600.00 HRV1.3 &...
  • Page 10: Hrv4, 4.1 & 4.25 Q Plus

    477.5 396.5 HRV4, 4.1 & 4.25 Q Plus 237.5 383.5 125.5 1150 HRV20 Q Plus...
  • Page 11: H200 Q Plus (Horizontal Unit)

    1004 H200 Q Plus (Horizontal Unit)
  • Page 12: Product Features

    Product Features Auto Setback Speed The following describes the controls and features of the auralite HRV Q Plus units and Setback Speed is used to reduce ventilation how they are controlled. Ensure all controls rates. Setback Speed is automatically are adequately labelled, indicating their set at the mid point between minimum function clearly.
  • Page 13: Summer Bypass

    Summer Bypass internal temperatures rise Automatic Frost Summer Bypass is designed to operate Protection will increase the supply ventilation during hot periods where fresh air can be flow rate back to the commissioned settings. vented straight into the property without Integrated Humidity Sensor being preheated by the extracted stale air.
  • Page 14: Installation

    Installation Unit Mounting Read and observe the guidance & safety notices listed in Warnings, Safety Information and Guidance . Do not remove the Port Covers, where fitted, until connecting ducting. Port Covers are fitted to prevent debris falling into the unit and causing blockages and damage: The mounting surface must be sufficiently strong to support the unit.
  • Page 15: Safety Bracket

    Safety Bracket The Safety Bracket(s) MUST be used. HRV20 Remove the rear Transport Feet to enable fitment of the Safety Brackets and remove the front Transport Feet and M6x40mm fixing screw and discard. Fit the supplied M6x10mm screws from the Safety Bracket Pack.
  • Page 16: Mounting H200

    Mounting H200 Read and observe the guidance & safety notices listed in Warnings, Safety Information and Guidance . The units are designed to be mounted on the underside of a horizontal surface. The mounting surface and fixings must be sufficiently strong to support the unit. The H200 unit is 32Kg, Consider the positioning of electrical services and the Condensate Drain when siting the unit.
  • Page 17: Condensate Drain

    Must be installed to have a 3 to 5° fall from the unit. Titon recommend the use of a diaphragm type waste valve, in place of a conventional ‘wet’ trap which could dry out; Such as a ‘Hepworth HepvO® Hygienic self sealing plastic waste valve’...
  • Page 18: Hrv1�3 & 1�35

    Other than the H200 all units are supplied as either Left Hand, Right Hand Units. Left Right Hand Hand Left / Right Hand Drain Connection & corresponding Ducting Connections HRV1.3 & 1.35 The Condensation Drain Pipe Is attached via a 15mm compression fitting HRV 1.6 1.65, 4, 4.1 &...
  • Page 19: Hrv20

    HRV20 Fit hose clamps around both Condensate Drain Sockets, ensuring they are pushed over the lip and aligned with recess in sheet metal casing Insert 22mm O/D PVC pipe into Condensate Drain Socket up to the stop, no more than 35mm of pipe should be inserted into Condensate Drain Socket.
  • Page 20: Horizontal Unit(S)

    Horizontal Unit(s) H200 The H200 is only available with one port configuration. Condensate Drain Highlighted Condensate output is a Ø21.4mm plastic pipe positioned on the end of the unit. Drain pipe must be fitted to the unit with a removable fitting.
  • Page 21: Ducting Connections

    Ducting Connections The HRV unit has a labels with the icons indicating which port is which. Read and observe the Warnings, Safety Information and Guidance. It is very important that ducting is connected to the correct ports in line with the icons below. Port Designations EXTRACT FROM DWELLING - This duct port is connected to the ducting that carries waste air from the ‘Wet Rooms’...
  • Page 22: Wiring Access

    Wiring Wiring Access All wiring must conform to current I.E.E. Wiring Regulations and all applicable national standards and Building Regulations. Read and observe the Warnings, Safety Information and Guidance. With the exception of the HRV20 all units use the same Electronics Terminal Enclosure. The compartment has two removable lids.
  • Page 23: Auralite

    auralite® auralite® connection at Indicator ref EE180 auralite® connection at Unit ref EE180...
  • Page 24: Switching & Controls

    Switching & Controls Volt-free control of SUMMERboost® using one way latching switch. usin TP 522 Latching SUMMERboost® switch SUMMERboost® switch connection ref EE178 Volt-free boost switching of MVHR controller PCB using single-pole switches TP 502, TP 503, TP 507 and / or TP500 / TP501 humidistat. There is maximum of 10 single pole switches or humidistats TP500/TP501...
  • Page 25 SWITCH POSITIONS 1 - Setback Speed 2 - Continuous Speed 3 - Boost Speed TP 508 Three position rotary switch U1 U2 U3 Three Position Rotary Switch TP 508 switching and connection ref EE175 SUMMERboost® Link Wire must be removed to enable SUMMERboost®. SUMMERboost®...
  • Page 26: Commissioning

    Commissioning Controls The fan speeds of the Titon HRV Q Plus will require adjustment to ensure the flow rates achieved provide adequate ventilation. The Titon HRV Q Plus has 2 standard fan speed settings Continuous Speed and Boost Speed. The Continuous Speed and Boost Speed are programmed by placing the controller into Program Mode via the Program/Run Switch and changing the position of rotary potentiometers.
  • Page 27: Boost Supply & Extract Speeds

    Following a controller reset the ventilation system will need to be fully commissioned. The procedure to reset the Titon HRV Q Plus controller is a simple three step operation. The unit will need to be powered up during the reset procedure.
  • Page 28: Maintenance

    Maintenance Routine Maintenance All ventilation units require periodic maintenance. Routine maintenance, apart from filter changes, must only be carried out by a suitably qualified and competent person. WARNING: The unit uses a ~230V supply and contains rotating mechanical parts. ISOLATE the unit from mains power supply and allow sufficient time for all moving parts to stop before undertaking any Servicing or Maintenance.
  • Page 29: Hrv20

    HRV20 Front Cover Removal ISOLATE the unit from mains power supply and allow sufficient time for all moving parts to stop Loosen the two corner screws located on the bottom front of the unit Completely remove the centre screw. Completely remove Front Cover top cap nuts.
  • Page 30: Filter Replacement

    The connected controller will indicate filter change required in line with the Filter Change Interval settings. Replacement Filters are available from Titon Direct. www.titondirect.co.uk Filters should be replaced with like for like components. Following filter replacement the HRV controller's Filter Warning should be reset, refer to Product Manual of controller for details.
  • Page 31: Hrv20

    HRV20 Titon HRV20 Q Plus Filters are available in two grades G4 x 2 and G4 + F7. Filter media should be replaced like for like. When replacing G4 + F7 filters make a note of the relative positions of the filters before removing.
  • Page 32: H200

    H200 The H200 can be specified with filters of different grades. Filters must be replaced with like for like replacements, failure to do so will result in changed system airflows and will necessitate the re-commissioning of the ventilation system. Type Part Number 2 Standard G4 panel filters XP2010173...
  • Page 33 This unit should be returned to your distributor or to a local recycling service. Respect the local environmental rules. MARKETING DIVISION 894 The Crescent, Colchester Business Park, Colchester, CO4 9YQ Tel: +44 (0) 1206 713800 Fax: +44 (0) 1206 543126 Email: ventsales@titon.co.uk Web: www.titon.com...
  • Page 34: Service Record

    Service Record Serviced By Company Name Date Notes...
  • Page 35 Serviced By Company Name Date Notes...
  • Page 36 Installed by: ©2023 TITON DO 5838 Issue 02-...