National Instruments CVS-1459 User Manual page 12

Compact vision system with usb3 vision and reconfigurable i/o
Table of Contents

Advertisement

Pin Number
Signal
32
Iso In 1 General purpose isolated input
33
C
ISO
34
Iso In 2 General purpose isolated input
35
Iso In 3 General purpose isolated input
36
C
ISO
37
Iso In 4 General purpose isolated input
38
Iso In 5 General purpose isolated input
39
C
ISO
40
Iso In 6 General purpose isolated input
41
Iso In 7 General purpose isolated input
42
C
ISO
43
Iso Out 6 General purpose isolated output
44
Iso Out 7 General purpose isolated output
Wiring an Isolated Input
You can wire an isolated input to a sourcing output device.
Caution
Voltage greater than 24 VDC may damage the NI CVS-1459.
Figure 10. Connecting an Isolated Input to a Sourcing Output Device
Sourcing
Output
Device
Table 6. Digital I/O Pin Descriptions (Continued)
Common ground reference for isolated inputs and outputs
Common ground reference for isolated inputs and outputs
Common ground reference for isolated inputs and outputs
Common ground reference for isolated inputs and outputs
Do not apply a voltage greater than 24 VDC to the isolated inputs.
Power Supply
Input
C
ISO
CVS
Description
Current
V
REF
Limiter
+
NI CVS-1459 User Manual | © National Instruments | 11

Advertisement

Table of Contents
loading

Table of Contents