National Instruments NI CVS-1458 Getting Started Manual

Compact vision system with gige vision and reconfigurable i/o

Advertisement

Quick Links

GETTING STARTED GUIDE
NI CVS-1458
Compact Vision System with GigE Vision and Reconfigurable I/O
The NI CVS-1458 is a compact vision system that acquires, processes, and displays images from
GigE Vision cameras. The NI CVS-1458 ships with preloaded Windows Embedded Standard 7
64-bit. This document explains how to install and configure the NI CVS-1458.
Required Components
The following items are necessary to set up and use the NI CVS-1458:
NI CVS-1458 device
One or two GigE Vision cameras
One CAT 5e or CAT 6 1000Base-T Ethernet cable per GigE Vision camera
One CAT 5 10/100Base-TX, CAT 5e, or CAT 6 1000Base-T Ethernet cable to connect the
device to a network.
A CAT 5e or CAT 6 1000Base-T Ethernet cable is required to achieve
Note
1,000 Mbps (Gigabit) Ethernet performance. CAT 5e and CAT 6 Ethernet cables
adhere to higher electrical standards required for Gigabit Ethernet communication.
CAT 5 cables are not guaranteed to meet the necessary requirements. While CAT 5
cables may appear to work at 1,000 Mbps, CAT 5 cables are likely to cause bit errors
resulting in degraded network performance.
Monitor
Keyboard
Mouse
A compatible power supply, such as the NI PS-15 Power Supply (part number 781093-01)
Two ferrites (part number 711849-01)

Advertisement

Table of Contents
loading

Summary of Contents for National Instruments NI CVS-1458

  • Page 1 NI CVS-1458 Compact Vision System with GigE Vision and Reconfigurable I/O The NI CVS-1458 is a compact vision system that acquires, processes, and displays images from GigE Vision cameras. The NI CVS-1458 ships with preloaded Windows Embedded Standard 7 64-bit. This document explains how to install and configure the NI CVS-1458.
  • Page 2: Optional Equipment

    Optional Equipment National Instruments offers the following products for use with the NI CVS-1458:  24 VDC, 1.25 A Desktop Power Supply (part number 782032-01)  NI PoE Power Supply to power the Power over Ethernet (PoE) ports (part number 783307-01 for DIN rail version or part number 783308-01 for desktop version) ...
  • Page 3: Electromagnetic Compatibility Guidelines

    Instruments could void your authority to operate it under your local regulatory rules. To ensure the specified EMC performance, operate this product only with Caution shielded cables and accessories. NI CVS-1458 Getting Started Guide | © National Instruments | 3...
  • Page 4: Configuring The Hardware

    Complete the following sections to wire power to the NI CVS-1458, connect cameras, and connect the NI CVS-1458 to a network. Figure 1 and Figure 2 show the features on the device. Figure 1. NI CVS-1458 Power Connectors and Reset Button...
  • Page 5: Connecting The System Power Supply

    44-pin Digital I/O Connector Connecting the System Power Supply Complete the following steps to supply power to the NI CVS-1458. Make sure the power source is turned off. Install one ferrite across the negative and positive leads of the power source, approximately 50 to 75 mm (2 to 3 in.) from the end of the power input wires, as shown in Figure 3.
  • Page 6: Connecting The Isolated Outputs Power Supply And Poe Power Supply

    0.2 to 0.25 N · m (1.8 to 2.2 lb · in.) of torque. Install the power connector plug into the SYSTEM power receptacle on the NI CVS-1458 chassis and tighten the connector screws to 0.4 N · m (3.5 lb · in.) of torque.
  • Page 7 0.2 to 0.25 N · m (1.8 to 2.2 lb · in.) of torque. Install the power connector plug into the ISO power receptacle on the NI CVS-1458 chassis and tighten the connector screws to 0.4 N · m (3.5 lb · in.) of torque.
  • Page 8: Connecting Gige Vision Cameras

    NI CVS-1458. Connect an Ethernet cable to a GigE Vision camera, then connect the other end to the NI CVS-1458 PoE PORT 0. Repeat this step for PoE PORT 1 if you are connecting two cameras. If the cameras support PoE, and a PoE power source is connected to the device, the PoE0 and PoE1 LEDs will illuminate.
  • Page 9 Digital I/O The 44-pin Digital I/O port on the NI CVS-1458 offers 8 isolated inputs, 8 isolated outputs, 2 bidirectional differential I/O (RS-422) or single-ended input lines which can be used with a quadrature encoder, and 8 bidirectional TTL lines. The Digital I/O port can be connected to any appropriate shielded device or connector block using a shielded cable.
  • Page 10 Table 1. Pin Location and Definition for the NI CVS-1458 Digital I/O (Continued) Location Number Signal Description Digital ground reference for TTL and differential I/O Diff 1- Bidirectional RS-422 I/O (negative side), or quadrature encoder phase B- Isolated power voltage reference output...
  • Page 11: Where To Go Next

    Where to Go Next The following documents and resources contain information you may find helpful as you use the NI CVS-1458 in an application. Refer to the National Instruments Product Manuals Library at for the most recent versions of product documentation.
  • Page 12: Worldwide Support And Services

    NI product. Refer to the Export Compliance Information at ni.com/legal/export-compliance for the National Instruments global trade compliance policy and how to obtain relevant HTS codes, ECCNs, and other import/export data. NI MAKES NO EXPRESS OR IMPLIED WARRANTIES AS TO THE ACCURACY OF THE INFORMATION CONTAINED HEREIN AND SHALL NOT BE LIABLE FOR ANY ERRORS.

Table of Contents