Troubleshooting; Tool Storage; Service Tools - Stanley TT46 User Manual

Hydraulic tie tamper
Hide thumbs Also See for TT46:
Table of Contents

Advertisement

clockwise. This will retract the valve stem.
3.
Screw the tester onto the breaker charging port. Twist the tester gauge
clockwise and read the pressure indicated on the gauge. Charge should
be 500-600 PSI (34-41 BAR).
Charge
4.
Retract the tester valve stem.
5.
Connect the charging assembly hose to the tester.
6.
Twist the tester gauge clockwise to advance the valve stem.
7.
Slowly open the snub valve and charge to 600-700 PSI (41-48 BAR).
8.
Close the snub valve, retract the tester valve stem and remove the tester
from the breaker charging port. Replace the charging plug.

Tool Storage

Clean the tool and store in a clean, dry space that is safe from damage.
Ensure the tool is secured and will not move during transport. An unsecured
tool could cause injury or damage to the tool.
Tool Disposal
Hydraulic Oil
Hydraulic oil can contaminate the air, ground and water if not properly
recycled. Recycle hydraulic oil in accordance with all State, Federal and local
laws, at your local oil recycling facility.
Hydraulic Hoses
Hang hydraulic hoses to drain. Collect the oil for recycling. Contact your local
municipal recycling authorities for an approved hydraulic hose recycling site.
Tool Body
Drain hydraulic oil from the tool, making sure to collect the oil for recycling.
Discharge the accumulator, disassemble the tool and dispose of all non-metal
parts. Recycle the metal components. Contact your local municipal recycling
authorities for recycling instructions.
Accessories
4 inch steel with "V" cut (18 inch overall length)
4 inch steel with "V" cut, Heavy Duty (18 inch overall length)
4 inch steel with "V" cut (21 inch overall length)
4 inch steel with "V" cut, Heavy Duty (21 inch overall length)
4 inch steel (24 inch overall length)
Anti-Vibration Handle Conversion Kit

Service Tools

Tamping sleeve tool
O-ring tool kit
Seal kit
Flow sleeve removal tube
Flow sleeve removal tool
Accumulator cylinder puller
Accumulator tester
Accumulator charge kit
Charging assembly
Flow and pressure tester
8 | TT46 User Manual

Troubleshooting

Problem
Tool does not run or
runs improperly.
44979
59034
44937
59033
33200
27680
01120
04337
04595
04910
04919
05640
02835
31254
15304
04182
Possible Cause
Solution
Ensure the power source
is delivering proper
The hydraulic power
flow and pressure. See
source is not running
"Specifications" on
or not running
page 7. Proper flow
properly.
and pressure maintain
proper tool speed. Check
regularly.
Turn off and disconnect
the tool from the
Couplers or hoses are
hydraulic power source.
blocked.
Inspect and ensure no
blockage exists.
Check accumulator
charge. Recharge
Low accumulator
if necessary. See
charge pressure.
"Accumulator Charge -
Detail D" on page 7.
Hydraulic oil is above
Provide an oil cooler
the max. operating
to maintain proper oil
temperature of 140°F
temperature.
(60°C).
Check the hydraulic
High Back Pressure.
system for excessive
back pressure.
Contact your STANLEY
Mechanical failure.
dealer for service.