March 2016
How to R emove the Functi on Pum p
How to Remove the Function
Pump
Bodily injury hazard. This
procedure requires specific repair
skills, lifting equipment and a
suitable workshop. Attempting
this procedure without these
skills and tools could result in
death or serious injury and
significant component damage.
Dealer service is strongly
recommended.
Note: When removing a hose assembly or fitting,
the O-ring (if equipped) on the fitting and/or hose
end must be replaced. All connections must be
torqued to specification during installation. Refer to
Specifications, Hydraulic Hose and Fitting Torque
Specifications.
Note: Perform this procedure with the engine off
and cool.
1
Open the access door above the hydraulic
tank.
2
Disconnect the battery from the machine.
Electrocution/burn hazard.
Contact with electrically charged
circuits could result in death or
serious injury. Remove all rings,
watches and other jewelry.
3
Tag and disconnect the wire harness from the
pump.
4
Tag and disconnect the case drain hose at the
top of the pump. Cap the fitting on the pump.
Note: Placing the open end of the case drain hose
below the hydraulic oil level in the hydraulic tank
will result in excessive hydraulic fluid leaking from
the hose. Do not lower the open end of the case
drain hose to below the fluid level of the hydraulic
tank until the hose is plugged.
Part No. 123701
5
Tag, disconnect and plug the large hydraulic
pump supply hose at the pump. Cap the fitting
on the pump.
Note: Placing the open end of the pump supply
hose below the fluid level in the hydraulic tank will
result in excessive hydraulic fluid leaking from the
hose. Do not lower the open end of the pump
supply hose to below the fluid level of the hydraulic
tank until the hose is plugged.
6
Tag, disconnect and plug the high pressure
hose at the pump. Cap the fitting on the
pump.
7
Tag and disconnect the transmission cooler
hoses at the transmission cooler. Cap the
fittings.
8
Remove the fasteners securing the pump to
the transmission. Remove the pump from the
machine.
GTH-1048 • GTH-1056
Service Manual
Hydraulic Pump
Bodily injury hazard. Spraying
hydraulic oil can penetrate and
burn skin. Loosen hydraulic
connections very slowly to allow
the oil pressure to dissipate
gradually. Do not allow oil to
squirt or spray.
Burn hazard. Contact with hot
engine components may cause
severe burns.
Courtesy of Crane.Market