ProcessMaster FEP630, HygienicMaster FEH630 ELECTROMAGNETIC FLOWMETER | SI/FEP630/FEH630/FM/CSA-EN REV. A
... 2 Device designs
... Version with remote mount design
The following table presents the combination of the FEP632, FEH632 sensor in explosion-proof design with the FET632 transmitter.
Sensor
ProcessMaster 630
FEP632-F2
in Ex area, Div. 2
USA, FM approval
Certificate: FM17US0062X
NI: CL I, Div 2, GPS ABCD T6...T1
DIP: CL II,III, Div 2, GPS EFG T6...T6...T3B
CL I, ZN 2, AEx ec IIC T6...T1
ZN 21, AEx tb IIIC T80°C...T165°C
Canada, cFM approval
Certificate: FM17CA0033X
NI: CL I, Div 2, GPS ABCD T6...T1
DIP: CL II,III, Div 2, GPS EFG T6...T3B
CL I, ZN 2, Ex ec IIC T6...T1 Gc
Ex tb IIIC T80°C...T165°C Db
Transmitter
FET632-F2
In Ex area, Zone 2, 22
USA, FM approval
Certificate: FM17US0062X
NI: CL I, Div 2, GPS ABCD T6
DIP: CL II,III, Div 2, GPS EFG T6
CL I, ZN 2, AEx ec IIC T6
ZN 21, AEx tb IIIC T80°C
Canada, cFM approval
Certificate: FM17CA0033X
NI: CL I, Div 2, GPS ABCD T6
DIP: CL II,III, Div 2, GPS EFG T6
Ex ec IIC T6 Gc
Ex tb IIIC T80°C Db
*
Single-compartment housing
** Dual-compartment housing
Change from one to two columns
HygienicMaster 630
FEH632-F2
in Ex area, Div. 2
USA, FM approval
Certificate: FM17US0062X
NI: CL I, Div 2, GPS ABCD T6...T1
DIP: CL II,III, Div 2, GPS EFG T6...T6...T3B
CL I, ZN 2, AEx ec IIC T6...T1
ZN 21, AEx tb IIIC T80°C...T165°C
Canada, cFM approval
Certificate: FM17CA0033X
NI: CL I, Div 2, GPS ABCD T6...T1
DIP: CL II,III, Div 2, GPS EFG T6...T3B
CL I, ZN 2, Ex ec IIC T6...T1 Gc
Ex tb IIIC T80°C...T165°C Db
FET632-Y0
outside the potentially explosive atmosphere
-
No Ex Approval!