Jackson TempStar Series Installation, Operation And Service Manual page 27

Door-type dishmachines
Table of Contents

Advertisement

DELIME INSTRUCTIONS
OPERATION
To delime the machine, follow the steps below. The tank capacities of the machine
DELIMING
can be found in the Specifications section of this manual.
1. Remove rinse arms and place in sink with deliming solution.
2. Disconnect or turn off chemical feeder pumps.
3. Add deliming solution per chemical supplier's instructions.
4. Close the door and turn the machine on in MANUAL mode.
5. Run the machine for the length of time recommended by the chemical supplier.
6. Flip the mode switch to AUTO to shut the unit off.
7. Open the door and step away for 5 minutes.
8. Inspect the inside of the machine. If the machine is not delimed, run again.
9. When clean, drain and re-fill the machine.
10. Run two cycles in AUTO to remove residual deliming solution.
11. Drain and re-fill the machine.
12. Flush rinse arms with water and replace.
Mode Switch
Power Switch
This equipment is not recommended for use with deionized water or other aggressive
fluids. Use of deionized water or other aggressive fluids will result in corrosion and
failure of materials and components. Use of deionized water or other aggressive fluids
will void the manufacturer's warranty.
20
07610-003-61-42-U

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Tempstar ltTempstar nbTempstar s

Table of Contents