Jackson hot water sanitizing undercounter dishmachines service manual (51 pages)
Summary of Contents for Jackson TEMPSTAR HH
Page 1
UPRIGHT DOOR DISHMACHINES TECHNICAL MANUAL INSTALLATION MANUAL FOR EXPORT UNITS SERVICE MANUAL FOR DOMESTIC UNITS ELECTRICALLY HEATED MODELS: TEMPSTAR HH TEMPSTAR HH NB STEAM HEATED MODELS: TEMPSTAR HH S Jackson MSC, LLC. P.O. BOX 1060 HWY. 25E BARBOURVILLE, KY. 40906...
The warranty registration card supplied with the machine must be returned to Jackson MSC within 30 days to validate the warranty. REPLACEMENT PARTS WARRANTY Jackson replacement parts are warranted for a period of 90 days from the date of installation or 180 days from the date of shipment from the factory, which ever occurs first.
Page 3
STOP! PARE! ARRET! CALL 1-888-800-5672 TO REGISTER THIS PRODUCT! FAILURE TO DO SO WILL VOID THE WARRANTY! LLAME AL 1-888-800-5672 PARA REGISTRAR ESTE PRODUCTO! AL NO HACERLO LA GARANTIA SERA ANULADA! S.V.P . APPELER 1-888-800-5672 POUR ENREGISTRER CE PRODUIT, LA GARANTIE SERA ANNULEE POUR TOUT PRODUIT NON- ENREGISTREE...
Page 4
REVISION MADE APPLICABLE REVISION DETAILS DATE 06-01-04 Change to new layout. Corrected amperage ratings, changed to thermostat bracket 05700-011-81-64, changed thermostat 05930-121-71-29 to ther- 05-20-05 mostat kit 06401-140-00-32, updated drawing for false panel installation, and added SDI override instructions. 01-17-06 7609 Added universal timer, parts &...
Page 5
TEMPSTAR HH = Electrically heated, hot water sanitizing, with booster heater, door-type dishmachine with a higher hood TEMPSTAR HH NB = Electrically heated, hot water sanitizing, no rinse booster, door-type dishmachine with a higher hood TEMPSTAR HH S = Steam heated, hot water sanitizing, door-type dishmachine with a higher hood Model: Serial No.:...
SECTION 1: SPECIFICATION INFORMATION TEMPSTAR HH DIMENSIONS (TOP MOUNT CONTROL BOX) LEGEND 4 [101mm] A - DRAIN 1 1/2" IPS B - WATER INLET 3/4" IPS C - ELECTRICAL CONNECTION All vertical dimensions are +/- 1/2" due to 3 [76mm] adjustable bullet feet.
SECTION 1: SPECIFICATION INFORMATION TEMPSTAR HH DIMENSIONS (SIDE MOUNT CONTROL BOX) LEGEND 4 [101mm] A - DRAIN 1 1/2" IPS B - WATER INLET 3/4" IPS C - ELECTRICAL CONNECTION All dimensions are in inches. All vertical dimensions are +/- 1/2" due to adjustable bullet feet.
64.1 CM 2 1/4” 10.2 CM 1 1/2” 3.8 CM 3/4” 1.9 CM TABLE DIMENSIONS CORNER INSTALLATION OPENING F (ROLL) TABLE DIMENSIONS CONNECTION TO DISHMACHINE TABLE DIMENSIONS STRAIGHT THROUGH INSTALLATION Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
However, rough handling by carriers or others may result in there being damage to the unit while in transit. If such a sit- uation occurs, do not return the unit to Jackson; instead, contact the carrier and ask them to send a representative to the site to inspect the damage to the unit and to complete an inspection report.
Advise all proper personnel of any problems and of the loca- tion of the service breaker. Replace the control box cover and tighten down the screws. Incoming Power Connection Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
If the water cannot get hot enough, your results may not be satisfactory. This is why Jackson recommends that if you have installed the machine in an area with hard water, that you also install some type of water treatment equipment to help remove the dissolved solids from the water before it gets to the dishmachine.
Operators should regularly inspect the pan strainer to ensure it has not become clogged. If the strainer does, it will reduce the washing capability of the machine. Instruct operators to clean out the pan strainer at regular intervals or as required by work load. Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
Using good prescrapping procedures and observing the results of individual racks of ware, operators will soon gain the expe- rience and knowledge required to ensure that the dishmachine operates at peak efficiency for your needs. Water hardness and detergent usage will also effect the results of the dishmachine. Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
Page 21
The dishmachines covered in this manual are designed to operate with a minimum of interaction with the operator. However, this does not mean that some items will not wear out in time. Jackson highly recommends that any maintenance and repairs not specifically discussed in this manual should be performed by QUALIFIED SERVICE PERSONNEL ONLY.
Page 23
1. Faulty rinse heater. Check element for continuity; if open, replace heater. 2. Misadjusted/faulty thermostat(s). Verify operation and setting of thermostats, replace if necessary. 3. Rinse thermometer is defective. Replace thermometer. Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
Page 24
2. No detergent/too much detergent. Adjust detergent concentration as required for the amount of water held by the machine. 3. Solid dispenser canister is empty. Replace the canister. Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
SECTION 5: PARTS SECTION TOP MOUNT CONTROL BOX ASSEMBLY Details for 460 Volt Control Box For a 460V Unit, Replace item 9 with items 45, 46 & 47. Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
Page 27
SECTION 5: PARTS SECTION TOP MOUNT CONTROL BOX ASSEMBLY (CONTINUED) Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
Page 28
Motor Contactor, SC-03Y, (460 Volt Unit Only) 05945-002-65-00 Din Rail 2-3/4” (460 Volt Unit Only) 05700-001-84-65 * For a 460V Unit, Replace item 9 with items 45, 46 & 47. Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
SECTION 5: PARTS SECTION SIDE MOUNT CONTROL BOX ASSEMBLY Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
Page 30
Light, Amber 05945-504-06-18 Cover, Dielectric Control Panel 05700-021-50-89 Contactor, 2 Pole 220V 20AMP (460 Volt Unit Only) 05945-002-65-00 Overload (460 Volt Unit Only) 05945-002-65-01 * Represents an item not shown. Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
Right/Left Front Hood Support Weldment 05700-002-17-68 Left Rear Outer Door Guide 05700-031-76-34 Left Rear Inner Door Guide 05700-031-76-33 Right Rear Outer Door Guide 05700-031-76-35 Right Rear Inner Door Guide 05700-031-76-32 Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
Page 33
Glide, Upper Door 05700-002-00-83 Door, Lower, Left Assembly 05700-002-01-32 Door, Lower, Left 05700-031-76-79 Glide, Lower Door 05700-002-23-64 Door Stop Weldment 05700-002-29-60 Door Stop 06401-003-08-69 Cantilever Arm Support Bracket 09515-003-15-64 Wear Button 05700-011-88-01 Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
Stand B, Steam Coil Support 05700-002-08-51 Stand A, Steam Coil Support 05700-002-08-50 Gasket, Steam Coil 4 per assembly 05700-001-17-86 Washer, Steam Coil Adapter, Steam Coil Nut 2 per assembly 2 per assembly 05700-001-17-87 05310-011-17-85 Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
Always refer to the wiring diagrams on the motor you are installing. If the motor you are installing has had the schemat- ic removed, contact Jackson MSC immediately for technical support. The Tempstar models covered in this manual come supplied with various heaters, depending on the characteristics of the machine.
1/4” from the bottom of the Tee. Tighten the Modified Compression Fitting as required. Attach to the incoming cold water line. Use pipe dope or thread tape as required to prevent any leaks. Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
Latch access hole The following instructions are for Tempstar HH models equipped with the Safety Door Interlock option. These instructions are to only be used in the event that the door interlock fails to unlatch and the doors are unable to be opened.
7. Re-install the screws for the rack assembly which will secure the false panel to the unit. 8. Re-assemble the rack track in an “L” shape for a corner operation. Bottom of False Panel Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
Page 55
SECTION 6: ELECTRICAL SCHEMATICS TEMPSTAR HH (TOP MOUNT CONTROLS) 208-230 VOLT - 60 HERTZ - SINGLE & THREE PHASE Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
Page 56
SECTION 6: ELECTRICAL SCHEMATICS TEMPSTAR HH (TOP MOUNT CONTROLS) 460 VOLT - 60 HERTZ - THREE PHASE Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
Page 57
SECTION 6: ELECTRICAL SCHEMATICS TEMPSTAR HH (UNIVERSAL TIMER) 208-230 VOLT - 60 HERTZ - SINGLE & THREE PHASE Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
Page 58
SECTION 6: ELECTRICAL SCHEMATICS TEMPSTAR HH (UNIVERSAL TIMER) 460 VOLT - 60 HERTZ - THREE PHASE Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
Page 59
SECTION 6: ELECTRICAL SCHEMATICS TEMPSTAR HH NB & HH LT (UNIVERSAL TIMER) 208-230 VOLT - 60 HERTZ - SINGLE & THREE PHASE Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
Page 60
SECTION 6: ELECTRICAL SCHEMATICS TEMPSTAR HH NB & HH LT (UNIVERSAL TIMER) 460 VOLT - 60 HERTZ - THREE PHASE Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
Page 61
SECTION 6: ELECTRICAL SCHEMATICS TEMPSTAR HH S (UNIVERSAL TIMER) 208-230 VOLT - 60 HERTZ - SINGLE & THREE PHASE Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
Page 62
SECTION 6: ELECTRICAL SCHEMATICS TEMPSTAR HH 208-230 VOLT - 60 HERTZ - SINGLE & THREE PHASE Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
Page 63
SECTION 6: ELECTRICAL SCHEMATICS TEMPSTAR HH 460 VOLT - 60 HERTZ - THREE PHASE Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
Page 64
SECTION 6: ELECTRICAL SCHEMATICS TEMPSTAR HH NB & HH LT 208-230 VOLT - 60 HERTZ - SINGLE & THREE PHASE WASH HEATER WASH MOTOR WASH HEATER CONTACTOR WASH MOTOR CONTACTOR CONTROL RELAY DISPENSER FUSE BLOCK POWER SWITCH DOOR SWITCH AUTO/MANUAL (DELIME) SWITCH...
Page 65
SECTION 6: ELECTRICAL SCHEMATICS TEMPSTAR HH NB & HH LT 460 VOLT - 60 HERTZ - THREE PHASE Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
Page 66
SECTION 6: ELECTRICAL SCHEMATICS TEMPSTAR HH S 208-230 VOLT - 60 HERTZ - SINGLE & THREE PHASE Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
Page 67
SECTION 6: ELECTRICAL SCHEMATICS TEMPSTAR HH 415 VOLT - 50 HERTZ - THREE PHASE 09905-002-32-44C Tempstar HH Series Technical Manual 7610-002-23-32 Issued: 09/14/2007 Revised: N/A...
Page 68
SECTION 7: JACKSON MAINTENANCE & REPAIR CENTERS...
Page 69
SECTION 7: JACKSON MAINTENANCE & REPAIR CENTERS ALABAMA TO FLORIDA ALABAMA CALIFORNIA P & D APPLIANCE GCS SERVICE INC. 4220-C ROSEVILLE ROAD PHILADELPHIA, PA JONES-McLEOD APPLIANCE BARKERS FOOD MACHINERY NORTH HIGHLANDS, CA (215)925-6217 SERVICES 95660 800-441-9115 1616 7TH AVE. NORTH...
Page 70
SECTION 7: JACKSON MAINTENANCE & REPAIR CENTERS FLORIDA TO MARYLAND JONES-McLEOD APPLIANCE HAWAII INDIANA CERTIFIED SERVICE CENTER 854 LAKESIDE DRIVE FOOD EQMT. PARTS & GCS SERVICE INC. 1051 GOODWIN DRIVE MOBILE, AL 36693 SERVICE CO. INDIANAPOLIS, IN LEXINGTON, KY 40505 (251) 666-7278 300 PUUHALE RD.
Page 71
SECTION 7: JACKSON MAINTENANCE & REPAIR CENTERS MARYLAND TO NEW YORK EMR SERVICE DIVISION MICHIGAN GCS SERVICE INC. NEW HAMPSHIRE 106 WILLIAMSPORT CIRCLE ST. LOUIS, MO SALISBURY, MD 21804 GCS SERVICE INC. (314) 638-7444 GCS SERVICE INC. (410) 543-8197 LIVONIA, MI...
Page 72
SECTION 7: JACKSON MAINTENANCE & REPAIR CENTERS NEW YORK TO PENNSYLVANIA B.E.S.T. INC. AUTHORIZED APPLIANCE OHIO OREGON 3003 GENESEE STREET SERVICECENTER BUFFALO, NY 14225 904 S. MARSHALL ST. CERTIFIED SERVICE CENTER RON'S SERVICE (716) 893-6464 WINSTON-SALEM, NC 27403 890 REDNA TERRACE...
Page 73
SECTION 7: JACKSON MAINTENANCE & REPAIR CENTERS RHODE ISLAND TO WISCONSIN RHODE ISLAND WHALEY FOODSERVICE GCS SERVICE INC. GCS SERVICE INC. REPAIRS HOUSTON, TX VIRGINIA BEACH, VA GCS SERVICE INC. 4740-A FRANCHISE STREET (713)785-9187 (757) 464-3500 EAST PROVIDENCE, RI N. CHARLESTON, SC 29418...
Page 74
SECTION 7: JACKSON MAINTENANCE & REPAIR CENTERS WISCONSIN TO WYOMING/INTERNATIONAL GENERAL PARTS, INC. W223 N735 SARATOGA DRIVE WAUKESHA, WI 53186 (262) 650-6666 (800) 279-9946 (262) 650-6660 FAX WYOMING HAWKINS COMMERCIAL APPLIANCE SERVICE 3000 S. WYANDOT ST. ENGLEWOOD, CO 80110 (303) 781-5548...
Need help?
Do you have a question about the TEMPSTAR HH and is the answer not in the manual?
Questions and answers