Boperating Range - Technibel REVE 247CH2O Technical Data & Service Manual

Cooling only model/heat pump model
Table of Contents

Advertisement

UNIT MODEL
FLAP MOTOR (FLP)
Model
Rating
Coil resistence (Ambient temp. 25°C)
4 WAYS VALVE (20S)
Model
Coil rating
Coil resistence (Ambient temp. 20°C)
HEAT EXCHANGER COIL
Coil
Rows
Fin pitch
Face area
PLATE EXCHANGER
Model
Plate
Gas connections
Water connections
SOLENOID VALVE
Model
Coil resistance (at 20° C)
Rating
Nominal input
FLOW SWITCH
Model
Water flow rate( ON )
Water flow rate( OFF )
Reed switch features :
HIGH PRESSURE SWITCH
OPERATING PRESSURE SETTING
Contact rating
B
OPERATING RANGE
Cooling only model
Cooling
Dry
Heat pump model
Cooling
Heating
Dry
Temperature
Indoor air intake temp.
Maximum
32° C DB/ 23° C WB
Minimum
19° C DB/ 14° C WB
Maximum
32° C BS/ 80% R.U.
Minimum
16° C BS/ 80% R.U.
Temperature
Indoor air intake temp.
Maximum
32° C DB/ 23° C WB
Minimum
19° C DB/ 14° C WB
Maximum
Minimum
Maximum
32° C BS/ 80% R.U.
Minimum
16° C BS/ 80% R.U.
REVE 247CH
WHT-BLU (respectively 4 wires) : 380 ± 7%
---
---
---
Aluminium plate fin / copper tube
mm
2
m
14
Øi mm
Øi mm
°C
220-230VAC~50Hz
l / min
l / min
V
250 VAC-200 VDC
W
OFF
bar
42 ± 1
27° C DB
//
6
REVE 237RH
O
2
MP24GA1
DC 12V
SQ-136
AC 220V, 50 Hz, 6W
1440 ± 5%
3
1,6
0,107
S09
20
9,6
14,3
1132/04A6
1050
68mA
CH23 IT
2
1,2
30
ON
33 ± 1,5
250 V - 6A
O
2

Hide quick links: