Tubing Connections - Milton Roy Roytronic A Series Instruction Manual

Electronic metering pumps
Table of Contents

Advertisement

INSTALLATION
3.3

Tubing Connections

DO NOT USE PLIERS OR PIPE WRENCH ON COUPLING NUTS OR FITTINGS.
To assemble tubing into the fittings:
1. Put coupling nut over tubing.
2. Press on Ferrule – Female about one inch (25 mm).
3. For
4. Firmly hand tighten the coupling nut onto the fitting. Tightening with pliers may cause
Replacement
Ferrules, and
Coupling Nuts
are available as
the following kit
numbers:
¼" Tube – 77382
" Tube – 77383
3
8
½" Tube – 77384
One kit is needed
for each end of
the tube.
10
Use only LMI tubing.
DO NOT USE CLEAR VINYL TUBING ON THE DISCHARGE SIDE OF THE
PUMP. The pressure created by the pump can rupture vinyl tubing, which is only for
connection to the return line of the FastPrime
Before installation, all tubing must be cut with a clean square end.
Valve and head connections from the factory are capped or plugged to retain pre-prime
water. Remove and discard these caps or plugs before connecting tubing.
" or 6mm OD tubing cut tubing so that only
1
4
from the Ferrule. For all other tubing push the tube to the bottom of the groove in the
Ferrule – Male.
the ferrules to break.
Coupling Nut
Ferrule - Female
Fitting
fitting.
" to
" (5-10 mm) protrudes
1
3
4
8
Ferrule - Female
Ferrule - Male

Advertisement

Table of Contents
loading

Table of Contents