Download Print this page

Installation Instructions - Insinger CA-3 Technical Manual

Pot and pan washers
Hide thumbs Also See for CA-3:

Advertisement

CA-3 & DA-3 POT AND PAN WASHERS

INSTALLATION INSTRUCTIONS

These installation instructions are intended for qualified
equipment installers.
PLACEMENT
Carefully uncrate the machine. Take caution not to
damage components which may be mounted on the
top or sides of the machine.
Set unit in place and adjust the feet to level the
machine.
TABLING
Load and unload tables should be pitched towards the
machine to return excess water into the machine.
Fasten the tables to the load and unload side of the
machine. Most installations require fastening the turn-
down lip of the dish tables to the side of the machine
with flathead counter-sunk screws.
The table design should provide horizontal clearance
of 30" for servicing.
ELECTRICAL CONNECTIONS
Connect electrical lines sized for the correct voltage,
current and phase of the machine. These should
agree with the machine requirements indicated on
the nameplate and labels on the control panel. The
below Fuse Sizing Chart should be used as a guide for
proper line protection.
MODEL
TYPE
Steam Heat
CA-3(C)
Electric Heat
Gas Heat
Steam Heat
DA-3
Electric Heat
CA-3 & DA-3 Technical Manual 2018
®
PART 2 INSTALLATION INSTRUCTIONS
FUSE SIZING CHART
208VAC / 3PH
25A
35A
25A
40A
60A
7
Machines not provided with a single-point connection
require two separate electrical connections for:
1. pumps and control circuit
2. wash tank heater(s)
If an electrical booster is provided connect the power
directly to the booster.
CAUTION:
Connections must be made to a circuit breaker or
fused disconnect as provided by the end-user and
required by local codes. A laminated wiring diagram
is inside the control panel.
CAUTION:
As with any 3 phase system, an electrician must
check all motors for proper phasing, i.e., Pump
motors must be running in direction indicated by
arrow on housing.
230VAC / 3PH
380VAC / 3PH
20A
35A
20A
35A
50A
www.insingermachine.com
460VAC / 3PH
15A
10A
20A
20A
15A
10A
25A
20A
30A
25A
800-344-4802