Safety; General Safety Warnings; Recommendations; Specific Safety Instructions - Heatrae Sadia Multipoint ECO 30L H Installation, Operation And Maintenance Manual

Table of Contents

Advertisement

How hot water can be drained. (see page 25 for
more details)
The type or characteristics of the Pressure
Reducing device and how to connect it; (see
Figure 9, page 24 for exploded view)
A discharge pipe connected to the pressure-
relief device is to be installed in a continuously
downward direction and in frost free environment;
(see page 14 for details)
Recommended minimum water pressure 0.08
MPa (0.8 bar). Max water pressure1.6 MPa (16
bar) (see table 1 page 5).
If the supply cord is damaged, it must be
replaced by the manufacturer, its service agent
or similarly qualified persons in order to avoid a
hazard.

2.1 General safety warnings

DANGER
This appliance is unvented and as such
becomes pressurised when in operation. The
combination of pressurisation and hot water
could lead to serious physical injury if the safety
instructions in this manual are not adhered to.
WARNING
Only competent persons having received
`
adequate training are permitted to work on
the appliance and the installation.
Do not tamper with any of the safety valves
`
or controls supplied with the cylinder.
Before any work, switch off the mains
`
supply to the appliance.
CAUTION
Do not operate immersion heater until the
appliance has been filled with water.

2.2 Recommendations

WARNING
When handling the unit, take appropriate
precautions for the weight of the unit. Weights
can be found in table 1, page 5.
4

2. Safety

CAUTION
Annual maintenance is recommended to be
carried out by a competent person, see section
9, page 24.

2.3 Specific safety instructions

WARNING
If water discharges from the Temperature/
`
Pressure Relief Valve on the appliance,
turn the water heater off. DO NOT turn off
any water supply. Contact a competent
Installer for unvented water heaters to
check the system.
DO NOT tamper with any of the safety
`
valves fitted to the system. If a fault is
suspected contact a competent Installer.
DO NOT bypass the thermal cut-out in any
`
circumstances.
Where the inlet supply to the Pressure
`
Reducing Valve is routed through a heated
space and is fitted with a check valve or
other fitting that would prevent backflow,
high pressures can be experienced in the
inlet pipe due to warming that can cause
damage to the PRV or other fittings on the
inlet supply. In these circumstances, the
installation of a means to accommodate
expansion and thus limit the pressure rise
in the inlet pipe is recommended
WARNING
This appliance is supplied with a factory
`
fitted
electronic
provides automatic control of legionella in
accordance with the "Approved Code of
Practice L8:
With the addition of this feature, the
`
obligation to control Legionella under the
provisions laid down by L8, Legionnaires'
disease: 'The control of legionella bacteria
water systems'. Approved Code of Practice
and guidance, within the hot water supply
network pipe work are not negated. It is
still the responsibility of the end user or
contracted support agency to manage this
requirement.
CAUTION
This appliance contains components that are
sensitive to Electrostatic Discharge.
To prevent damage to these components wear
ESD wrist strap when servicing this appliance.
thermostat