Download Print this page
Panasonic ECONAVI CZ-CENSC1 Installation Instructions Manual

Panasonic ECONAVI CZ-CENSC1 Installation Instructions Manual

Hide thumbs Also See for ECONAVI CZ-CENSC1:

Advertisement

Quick Links

AMP Air Conditioning

Installation Instructions

ECONAVI Sensor
Model No. CZ-CENSC1
F616629
ENGLISH
Read through the Installation Instructions before you proceed
with the installation. In particular, you will need to read under the
"Safety Precautions"on EN 4.
FRANÇAIS
Lisez les instructions d'installation avant de commencer
l'installation. En particulier, vous devez lire la section « Consignes
de sécurité » en page 19.
ESPAÑOL
Lea las Instrucciones de instalacion antes de proceder con la
instalacion del equipo. En concreto, deberá leer detenidamente la
sección "Precauciones de seguridad" situada en la página 36.
DEUTSCH
Lesen Sie die Einbauanleitung, bevor Sie mit der Installation
beginnen. Insbesondere müssen die „Sicherheitsvorkehrungen"
auf Seite 53 gründlich durchgelesen werden.
ITALIANO
Leggere le Istruzioni di installazione prima di procedere con
l'installazione. Prestare particolare attenzione alla sezione
"Precauzioni di Sicurezza" a pagina 72.
PORTUGUÊS
Leia cuidadosamente as instruções de instalação antes de
prosseguir com a instalação. Em particular, é necessário ler as
informações na secção "Precauções de segurança" na página 89.
E
.
,
"
"
3 ~ 17
EN
EN
18 ~ 34
FR
FR
35 ~ 51
ES
SP
52 ~ 70
DE
DE
71 ~ 87
IT
IT
88 ~ 104
PT
PT
105 ~ 122
GR
GK
1 6.
www.ampair.co.uk | sales@ampair.co.uk

Advertisement

loading

Summary of Contents for Panasonic ECONAVI CZ-CENSC1

  • Page 1: Installation Instructions

    ENGLISH 3 ~ 17 Read through the Installation Instructions before you proceed with the installation. In particular, you will need to read under the Installation Instructions “Safety Precautions”on EN 4. ECONAVI Sensor FRANÇAIS 18 ~ 34 Model No. CZ-CENSC1 Lisez les instructions d'installation avant de commencer l'installation.
  • Page 2: Table Of Contents

    Contents Safety Precautions Supplied accessories & Parts Name ..........3 Read before installation Safety Precautions ................4 Read the Installation Instructions carefully to install the unit Installation Precautions ..............6 correctly and safely. Mounting ...................9 Be sure to read the Safety Precautions in particular before installation. Settings (For CZ-RTC3) ..............12 After the installation is complete, perform test operation to con rm Test operation (For CZ-RTC3) ............15...
  • Page 3: Installation Precautions

    CAUTION Installation Precautions Dimensions Do not use at the following locations. Locations where condensation occurs Locations where ammable gases, etc. may leak Locations where corrosive gases, etc. may leak Locations with lots of water or oil droplets (including machine oil) Locations where voltage uctuation frequently occurs Locations where there is a machine producing electromagnetic radiation...
  • Page 4 Wiring for the sensor unit Attention - Wiring diagram Be careful not to connect cables to other terminals of indoor units (e.g. power source wiring terminal). Malfunction may occur. Terminals for RC wiring Sensor unit Do not bundle together with the power source wiring or store in the Indoor unit same metal tube.
  • Page 5: Mounting

    2.1 Exposed type Mounting Preparation: Make 2 holes for screws using a Phillips-head screwdriver. 1. Remove the bottom case. Mount the bottom case Flat-blade to the wall. screwdriver Cut here with a nipper and remove the burr with Mount the top case. a le.
  • Page 6: Settings (For Cz-Rtc3)

    2.2 Embedded type Settings (For CZ-RTC3) Preparation: Make 2 holes for screws using a Phillips-head screwdriver. RC. setting mode (ECONAVI activation for remote controller) 1. Press and hold the 3 buttons for 4 seconds or more simultaneously. Mount the top case. Mount the bottom case to the wall.
  • Page 7 Detailed settings (ECONAVI activation for indoor unit, Absence ECONAVI info. (ECONAVI function ON/OFF, Absence mode setting, mode setting, Start time of Absence mode) Start time of Absence mode) 1. Repeat steps 1 to 2 of RC. setting mode. *This menu will not appear unless ECONAVI is enabled by setting (Select [8.Detailed settings].) Code no.
  • Page 8: Test Operation (For Cz-Rtc3)

    Code Test operation (For CZ-RTC3) Preparation: Turn on the circuit breaker of units and then turn Data shows the state of the sensor unit. the power on. After the power is turned on, ECONAVI sensor unit 0000 not connected operation is ignored for appro . 90 seconds because settings are 0001 normal state being made.
  • Page 9: Speci Cations

    DC16 V (Supplied from indoor unit) Connections 1 sensor per indoor group NOTICE The English te t is the original instructions. Other languages are translations of the original instructions. Panasonic Corporation 2014 Printed in China © T0902-1 EN 17 AMP Air Conditioning...