Wiring diagram
The diagram below shows how to wire 8KW and 9KW electri ed locks.
8WDTL
Door transfer loop
Brown
(common)
Orange
(NO)
Green
(NC)
RQE (Request-to-exit) wires
are normally used with
access control systems.
Figure 1—Wiring diagram for 8KW and 9KW electri ed locks (9KW with RQE shown)
Electrical requirements
The following table describes the voltage and current speci cations
for the 8KW and 9KW locks, with RQE (REX) switch, and
door monitoring switch.
Unit
Voltage
8KW (RQE not avail-
24 volts AC or DC 0.18 amp continu-
able)
9KW with and with-
24 volts AC or DC 0.18 amp continu-
out RQE
RQE switch
30 volts AC or DC
maximum
T56090/Rev D 1800760 ER-7991-19 Jan 2015
Wiring Instructions for 8KW and 9KW Series
Electri ed Cylindrical Locks with Request-to-exit
Run wires through the door or
mount wires to the door sur-
face with wire molding.
To nd the correct wire gauge
for wire runs, see Figure 2 on
the reverse side.
Current
ous duty
ous duty
0.7 amp inductive
0.7 amp resistive
BEST ACCESS SYSTEMS
A Product Group of Stanley Security Solutions, Inc
*Note: In some door applications (for
example re doors), it may not be
possible to make extra holes into the
door. In such scenarios, the TCM may
be installed in a secure location at no
more than 20 feet from the door.
TCM (Temperature
Control Module)
Insert TCM into the
1" dia extension.*
(1" dia x 3" deep hole)
Electri ed cylindrical
chassis — 9KW shown
with RQE
Power Supply
24 Volts AC or DC
Ceiling
RQE (Request-to-exit) wires
— Over