Scan accuracy
The  detection  precision  depends  of  the  sensor  model.    Each  model  has  a  different  accuracy  of 
detection.    The  numbers  of  cells  are  the  same  for  all  models.    As  the  field  of  view  increases  the 
accuracy decreases. 
For each model, five different modes of scan can be selected.  The five modes are: 
Coarse   
Standard 
Fine 
 
Standard HS 
Fine HS  
 
The minimum detectable object dimensions are: 
 
Head Sensor 
P150
P225
P300
P450
P600
  
P150
P225
P300
P450
P600
 
The accuracy specified in the table is reachable, but under specific conditions only. To obtain a valid 
detection under all possible environment and condition, please add 0.025 in. (0.5mm) for each value 
shown in the table. When you are in Standard mode, the accuracy is true if you are centered between 
the emitter and receiver and within 1/3 of the distance between the emitter and receiver; and ¼ of 
the distance is you are in Fine mode.  This restriction comes from the cross scan effect. 
 
 
User Manual        
 
 
 
: Scan with the entire receiver's cells available.  (1500 scans/sec.) 
: Scan with the entire emitter's LEDs available.     (800 scans/sec.) 
: Cross scan the entire emitter and receiver cells.   (400 scans/sec.) 
: Scan in standard mode ½ of the field of view.  (1400 scans/sec.) 
: Cross scan in fine mode ¼ of the field of view.  (1400 scans/sec.) 
Coarse 
Standard & Standard HS 
0.4 
0.6 
0.8 
1.2 
1.6 
  
10 
15 
20 
30 
40 
 
    
   25  
 
 
Scan Accuracy 
0.2 
0.3 
0.4 
0.6 
0.8 
  
7.5 
10 
15 
20 
   
Module SIM‐P
 
  
Fine & Fine HS 
  
0.1 
0.15 
0.2 
0.3 
0.4 
  
2.5 
3.75 
7.5 
10 
Version 1.3  
  