This installation guide provides instructions for
installation, startup and adjustment. To receive a copy
of the instruction manual, contact your local Sales
Office or view a copy at www.fisherregulators.com. For
further information refer to: Type LR128 Instruction
Manual, D103578X012.
P.E.D. Categories
This product may be used as a pressure accessory
with pressure equipment in the following Pressure
Equipment Directive 97/23/EC categories.
PRODUCT SIZE
DN 25 and 50 / 1 and 2 in.
DN 80 and 100 / 3 and 4 in.
Specifications
Main Valve Body Sizes, End Connection Styles
and Body Ratings
(1)
See Table 1
Maximum Control Pressure
See Tables 1, 2 and 5
Minimum Set Pressure
1.7 bar / 25 psig
Set Pressure or Backpressure Control Ranges
See Table 4
Temperature Capabilities
See Table 3
Installation
!
Only qualified personnel shall install or
service a relief valve or backpressure
regulator. Relief valve or backpressure
regulator should be installed, operated
and maintained in accordance with
international and applicable codes
and regulations and Emerson Process
Management Regulator Technologies,
Inc. (Emerson™) instructions.
If using a relief valve or backpressure
regulator on a hazardous or flammable
fluid service, personal injury and
property damage could occur due to
fire or explosion of vented fluid that
may have accumulated. To prevent
1. The pressure/temperature limits in this Installation Guide and any applicable standard or code limitation should not be exceeded.
CATEGORY
FLUID TYPE
SEP
Liquid
II
Liquid
(1)
(1)
(1)
WARnInG
www.fisherregulators.com
such injury or damage, provide piping
or tubing to vent the fluid to a safe,
well-ventilated area or containment
vessel. Also, when venting a hazardous
fluid, the piping or tubing should be
located far enough away from any
buildings or windows so to not create
a further hazard and the vent opening
should be protected against anything
that could clog it.
Personal injury, equipment damage
or leakage due to escaping fluid
or bursting of pressure-containing
parts may result if this relief valve
or backpressure regulator is
overpressured or is installed where
service conditions could exceed the
limits given in the Specifications
section or where conditions exceed
any ratings of the adjacent piping or
piping connections.
To avoid such injury or damage,
provide pressure-relieving or pressure-
limiting devices (as required by
the appropriate code, regulation or
standard) to prevent service conditions
from exceeding limits.
(1)
Additionally, physical damage to the
relief valve or backpressure regulator
could result in personal injury and
property damage due to escaping fluid.
To avoid such injury and damage,
install the relief valve or backpressure
regulator in a safe location.
Clean out all pipelines before installation of the
relief valve or backpressure regulator and check to
be sure the relief valve or backpressure regulator
has not been damaged or has collected foreign
material during shipping. For NPT bodies, apply pipe
compound to the external pipe threads. For flanged
bodies, use suitable line gaskets and approved
piping and bolting practices. Install the relief valve
or backpressure regulator in any position desired,
unless otherwise specified, but be sure flow through
the body is in the direction indicated by the arrow
on the body.
Type LR128

Advertisement

loading

Summary of Contents for Emerson FISHER LR128 Series

  • Page 1 For flanged international and applicable codes bodies, use suitable line gaskets and approved and regulations and Emerson Process piping and bolting practices. Install the relief valve Management Regulator Technologies, or backpressure regulator in any position desired, Inc.
  • Page 2 Type LR128 Table 1. Type LR128 Main Valve Body Sizes, End Connection Styles, Structural Design Ratings and Maximum Operating Inlet Pressures MAxIMUM OPERATInG MAxIMUM MAIn VALVE STRUCTURAL RELIEF (InLET) MAIn VALVE OPERATInG OUTLET BODY SIZE DESIGn RATInG PRESSURE InCLUDInG EnD COnnECTIOn STYLE PRESSURE BODY MATERIAL BUILD-UP...
  • Page 3 Type LR128 Parts List Type LR128 Main Valve Description Valve Body Bonnet Assembly Cap Screw Hex Nut Top Plug O-ring Cage Cage O-ring Diaphragm O-ring Bottom Plug Main Valve Spring Top Plug O-ring Flanged Hex Nut Stem Back-up Ring Upper Spring Seat O-ring Indicator Fitting Indicator Washer...
  • Page 4 For further information visit www.fisherregulators.com The Emerson logo is a trademark and service mark of Emerson Electric Co. All other marks are the property of their prospective owners. Fisher is a mark owned by Fisher Controls International LLC, a business of Emerson Process Management.