Viking E-1600A-BLT-EWP Product Manual page 10

Ada compliant emergency tower phones
Hide thumbs Also See for E-1600A-BLT-EWP:
Table of Contents

Advertisement

F. Timing/Dialing Options
There are six positions in the timing/dialing options. To program these options, enter the six desired timing/dialing
numbers followed by #18. The six available timing/dialing options are defined as follows:
Factory Default Setting: 2 + 3 + 4 + 7 + 2 + 1
Talk/Listen Delay
Call Length
Silence Time Out
Dial Next Number on Ring No Answer
Dial Next Number on Busy
Future Use (set to 1)
Setting A - Talk/Listen Delay
This feature selects switching time between talk and listen modes (VOX switching time).
Use chart at the right. * Note: The factory default is .2 seconds.
Setting B - Call Length Time Out
This feature selects the maximum length of time that calls can be connected. Programmable
in increments of 1 minute up to a maximum of 9 minutes (Touch Tones 1 - 9). Program 0 in
this location to disable the call length time out. With the call length disabled, the 1600A
series phone must rely on a CPC signal, busy signal, silence or return to dial tone to hang-
up. Use chart at the right. * Note: The factory default is 3 minutes.
Setting C - Silence Time Out
This feature selects the length of time that calls will remain connected without voice activity.
Programmable in increments of 10 seconds up to a maximum of 90 seconds (Touch Tones
1 - 9). To disable the silence time out, program 0 in this location. Use chart at the far right.
* Note: The factory default is 40 seconds.
Setting D - Dial Next Number on Ring No Answer
If enabled and a ring-no-answer is detected, the 1600A series phone
will dial the next programmed speed dial number, and continue to
cycle through the emergency numbers until a call is completed.
* Note: Factory set to redial if not answered after 7 rings.
(memory location #18)
Dial: A + B + C + D + E + F + # + 1 + 8
Touch Tone
1 or 0
2, 3, 4... 9
10
Enter Timing/Dialing Settings Here:
A
B
C
D
E
F
Touch
Talk/Listen
Tone
1
2
3
4
5
6
7
8
9
Touch
Call Length
Tone
Time Out
0
Disabled
1
2
3
4
5
6
7
8
9
Touch
Silence
Tone
Time Out
0
Disabled
1
10 sec
2
02 sec*
3
03 sec
4
40 sec*
5
50 sec
6
60 sec
7
70 sec
8
80 sec
9
90 sec
Setting D
Disabled
Dials second number after
2, 3, 4...9 rings respectively*
#18
Delay
.1 sec
.2 sec*
.3 sec
.4 sec
.5 sec
.6 sec
.7 sec
.8 sec
.9 sec
1 min
2 min
3 min*
4 min
5 min
6 min
7 min
8 min
9 min